SolarEdge EV Series Installation Manual page 73

Charging single phase inverter with setapp configuration
Table of Contents

Advertisement

72
  EV Charger-related Troubleshooting
Error code
Internal Error
1Cx4; 1Cx5;
1Cx12 -1Cx13
Disconnect from EV
1CxB/D; 1Cx10 -
Interface Error (Pilot) Press
1Cx11
Press Charge Now
Ground Disconnected
1Cx6
Disconnect from EV
1Cx7
Over Temperature
Under Voltage
1CxA
Press Charge Now
Displayed Error message
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1
Description and Troubleshooting
-or-
Tap Charge Now on the EV
Charger tab of the Monitoring
App
Internal error.
Disconnect the EV Charger cable
from the vehicle.
Turn the inverter AC circuit
breaker OFF and ON.
Reconnect the EV Charger Cable
to the vehicle
Press the Charge Now
pushbutton on the Connection
Unit with Safety Switch, see
Figure 10
-or-
Tap Charge Now on the EV
Charger tab of the Monitoring
App
Ground Disconnected.
Disconnect the EV Charger cable
from the vehicle.
Contact SolarEdge Support.
EV Charger over temperature
Verify proper clearances around the
inverter and EV Charger Cable.
After verification reconnect the EV
charger cable to the EV.
EV Charger AC voltage too low.
Press the Charge Now
pushbutton on the Connection