SolarEdge EV Series Installation Manual page 65

Charging single phase inverter with setapp configuration
Table of Contents

Advertisement

64
  Creating an Ethernet (LAN) Connection
 3. Remove the plastic seal from one of the large openings.
 4. Remove the rubber fitting from the gland and insert the CAT5/6 cable through the
gland and through the gland opening in the inverter.
 5. Insert the cable through the opening in the Connection Unit with Safety Switch
towards the communication board.
 6. Push the cable into the cut opening of the rubber fitting.
 
 
 
CAT5/6 standard cables have eight wires (four twisted pairs), as shown in the diagram
below. Wire colors may differ from one cable to another. You can use either wiring
standard, as long as both sides of the cable have the same pin-out and color-coding.
RJ45 Pin #
1
White/Orange
2
Orange
(1) The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables
depends on the switch capabilities.
Figure 24: Communication glands and rubber fitting
(1)
Wire Color
T568B
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1
T568A
White/Green
Green
10Base-T Signal
100Base-TX Signal
Transmit+
Transmit-