Summary of Contents for Vertiv NetSure PSS12/2200-19BC
Page 1
NetSure™ +12 VDC Bulk Output Power System Installation and User Manual (UM588706000), Revision H Specification Number: 588706000 Model Number: PSS12/2000-19BC, PSS12/2200-19BC, PSS12/2000-19B, PSS12/2200-19B...
Page 2
The information contained in this document is subject to change without notice and may not be suitable for all applications. While every precaution has been taken to ensure the accuracy and completeness of this document, Vertiv Co. assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
SCC Controller Ethernet Connection ...................... 19 System Interconnections ............................ 19 AC Input and AC Input Equipment Grounding Connections to Module Mounting Assembly(s) ......................21 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 4
Contact Information ............................41 SCC Controller, Rectifier Module, and BBU Module ............41 System Troubleshooting Information ..................... 41 Replacement Information ..........................41 Replacement Procedures ..........................41 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
SAFETY! Informs the reader of general safety information, reminders, precautions, or policies not related to a particular source of hazard or to fire safety. (ISO, ANSI, OSHA) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
DANGER! Follow local lockout/tagout procedures to ensure DC branch circuit protection devices remain de- energized during installation at loads, as required. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
WARNING! Installation or removal of equipment containing static sensitive components requires careful handling. Before handling any equipment containing static sensitive components, read and follow the instructions contained on the Static Warning Page. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Before touching any equipment containing static sensitive components, discharge all static electricity from yourself by wearing a wrist strap grounded through a one megohm resistor. Some wrist straps, such as Vertiv Energy Systems Inc. Part Number 631810600, have a built-in one megohm resistor; no external resistor is necessary.
CAN bus exists per module mounting assembly, rectifiers load share per module mounting assembly, and rectifiers are load managed via an SCC per module mounting assembly. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 10
The BBU module is designed to provide 3 kW of 12 VDC power for a minimum of 90 seconds, per module. Refer to the BBU Instructions (UM1B123000) for more information. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Installing the Modules Rectifier Modules Installed, as required BBU Modules Installed, as required Initially Starting the System System Started, Configured, and Checked Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Do not attempt to install the system if damage is apparent. If any damage is noted, file a damage claim with the shipping agency within 24 hours and contact Vertiv Energy Systems Inc. to inform them of the damage claim and the condition of the equipment.
Precautions for the BBU to ensure safe arrival have been taken including UN/DOT packaging. If the packaging material is damaged, identify the unit and see if the device has damage. If the unit is physically damaged, contact Vertiv Energy Systems Inc. to inform them of the damage and the condition of the equipment. NOTE! The BBU should never be opened without Vertiv Energy Systems Inc.
Page 14
IT rack. Secure the front mounting flanges to the IT rack with the furnished cage nuts and screws. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
SCC Controller Instructions (UM1M520HNA). For rectifier module installation instructions, refer to rectifier module Instructions (UM1R123000). Refer to Figure 4 and install P/N 561578 Open Compute Rack shipping support bracket. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 16
Figure 4: Installing P/N 561578 Shipping Support Bracket Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Figure 6. These busbars provide clearance holes or slots for installation of customer-provided two hole lugs. Customer must order or supply lugs and lug mounting hardware. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 19
GND / Return Bus lugs and lug mounting hardware.) Maximum Lug Width: 1”. Torque: 80 in-lbs. Rear (List 1 Shown, other Lists Similar) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
External Alarm, Reference, Monitoring, and Control Connection Points Locations Refer to Figure 7. Figure 7: External Alarm, Reference, Monitoring, and Control Connection Points Locations Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
As each module mounting assembly is interconnected, remove the termination resistor from the main module mounting assembly and plug it into the appropriate connector on the last module mounting assembly as shown in Figure 8. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
DANGER! Adhere to the “Important Safety Instructions” presented at the front of this document. NOTE! A grounding conductor must be provided with each AC input feed. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 24
One M4 stud and hardware. Wire Size Capacity: 16 to 4 AWG. Torque: 1.7 Nm (15 in-lbs.) Torque: 2.5 to 3.0 Nm (22.1 to 26.5 in-lbs.) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 25
One M4 stud and hardware. 16 to 4 AWG. Torque: 1.7 Nm (15 in-lbs.) Torque: 2.5 to 3.0 Nm (22.1 to 26.5 in-lbs.) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 26
One M4 stud and hardware. Torque: 1.7 Nm (15 in-lbs.) 16 to 4 AWG. Torque: 2.5 to 3.0 Nm (22.1 to 26.5 in-lbs.) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 27
One M4 stud and hardware. 16 to 4 AWG. Torque: 1.7 Nm (15 in-lbs.) Torque: 2.5 to 3.0 Nm (22.1 to 26.5 in-lbs.) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 28
50 Hz / 60 Hz, Three Phase L1 - L2: Position #1 - #3 L2 - L3: Position #4 - #6 L1 - L3 : Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 29
4-Wire + PE, 50 Hz / 60 Hz L1 - N: Position #1 - #3 L2 - N: Position #4 - #6 L3 - N: Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 30
50 Hz / 60 Hz, Three Phase L1 - L2: Position #1 - #3 L2 - L3: Position #4 - #6 L1 - L3 : Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 31
4-Wire + PE, 50 Hz / 60 Hz L1 - N: Position #1 - #3 L2 - N: Position #4 - #6 L3 - N: Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 32
1325 A (15.9 kW). L1 - L2: Position #1 - #3 L2 - L3: Position #4 - #6 L1 - L3 : Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 33
50 Hz / 60 Hz, Three Phase L1 - L2: Position #1 - #3 L2 - L3: Position #4 - #6 L1 - L3 : Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 34
AC input protection devices. Figure 19 AC Input Connections to a 588706000 List 22, 32 Module Mounting Assembly Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 35
208 VAC, 50 Hz / 60 Hz, Three Phase Y L1 - L2: Position #7 L2 - L3: Position #8 L1 - L3: Position #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 36
Spec. No. 588706000 List 24 Module Mounting Assembly provides an AC input line cord and plug. Refer to Figure 21 for wiring details. Figure 21 AC Input Connections to a 588706000 List 24 Module Mounting Assembly Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 37
4-Wire + PE, 50 Hz / 60 Hz L1 - N: Position #1 - #3 L2 - N: Position #4 - #6 L3 - N: Position #7 - #9 Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
For SCC controller installation instructions, refer to SCC Controller Instructions (UM1M520HNA). For rectifier module installation instructions, refer to rectifier module Instructions (UM1R123000). For BBU module installation instructions, refer to BBU module Instructions (UM1B123000). Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
The BBU LED’s will be as follows if the ambient temperature is below 22 °C. The red LED can be illuminated for up to 30 minutes due to an initialization period and the yellow LED should be illuminated during this Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Page 40
Status and Alarm Indicators Component Indicator Normal State Status (Green) Warning Controller (Yellow) Alarm (Red) Power (Green) Protection/ Rectifier and Warning BBU Modules (Yellow) Alarm (Red) Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
SCC Controller, Rectifier Module, and BBU Module Refer to the separate instruction documents for descriptions of the local indicators located on these units. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
When the BBU is not plugged into a rack, there will be no external LEDs illuminated to conserve power. If BBU’s are stored, they will periodically need a refreshing charge. Refer to the BBU Instructions (UM1B123000) for more information. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
BBU modules are expected to have a finite operational life, depending on discharge cycles and duration. The SCC controller provides a replacement alarm. Replace the BBU modules when the SCC controller activates a replacement alarm. Vertiv | NetXtend +12 VDC Bulk Output Power System Installation and User Manual (UM588706000) | Rev. H...
Need help?
Do you have a question about the NetSure PSS12/2200-19BC and is the answer not in the manual?
Questions and answers