Unit: kW, °C
• TC: Total Capacity (kW), SHC: Sensible Heat Capacity (kW).
• The data is based on the following conditions:
Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit - Indoor unit]
MODEL: AUU7RLF
Outdoor temperature
(°CDB)
TC
-10.0
1.72
-5.0
1.72
0.0
1.72
5.0
1.72
10.0
1.72
15.0
1.72
20.0
1.72
25.0
1.72
30.0
1.72
35.0
1.72
40.0
1.63
46.1
1.54
MODEL: AUU9RLF
Outdoor temperature
(°CDB)
TC
-10.0
2.21
-5.0
2.21
0.0
2.21
5.0
2.21
10.0
2.21
15.0
2.21
20.0
2.21
25.0
2.21
30.0
2.21
35.0
2.21
40.0
2.09
46.1
1.97
MODEL: AUU12RLF
Outdoor temperature
(°CDB)
TC
-10.0
2.94
-5.0
2.94
0.0
2.94
5.0
2.94
10.0
2.94
15.0
2.94
20.0
2.94
25.0
2.94
30.0
2.94
35.0
2.94
40.0
2.78
46.1
2.62
6-2. Cooling capacity
17.8 / 12.2
21.1 / 15.6
SHC
TC
SHC
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.16
1.95
1.33
1.04
1.84
1.19
0.93
1.74
1.06
17.8 / 12.2
21.1 / 15.6
SHC
TC
SHC
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.47
2.49
1.67
1.32
2.36
1.50
1.17
2.22
1.33
17.8 / 12.2
21.1 / 15.6
SHC
TC
SHC
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.93
3.32
2.20
1.73
3.14
1.97
1.54
2.97
1.76
Indoor temperature (°CDB / °CWB)
23.9 / 17.2
26.7 / 19.4
TC
SHC
TC
SHC
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
2.05
1.53
2.20
1.71
1.94
1.37
2.08
1.53
1.83
1.22
1.96
1.37
Indoor temperature (°CDB / °CWB)
23.9 / 17.2
26.7 / 19.4
TC
SHC
TC
SHC
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.63
1.93
2.81
2.17
2.49
1.73
2.66
1.94
2.35
1.54
2.51
1.73
Indoor temperature (°CDB / °CWB)
23.9 / 17.2
26.7 / 19.4
TC
SHC
TC
SHC
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.50
2.54
3.75
2.85
3.32
2.27
3.55
2.55
3.13
2.02
3.35
2.27
- 181 -
29.4 / 21.7
32.2 / 22.8
TC
SHC
TC
SHC
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.35
1.88
2.42
2.15
2.22
1.68
2.29
1.92
2.10
1.49
2.16
1.71
29.4 / 21.7
32.2 / 22.8
TC
SHC
TC
SHC
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
3.01
2.37
3.10
2.71
2.85
2.12
2.93
2.43
2.68
1.89
2.77
2.16
29.4 / 21.7
32.2 / 22.8
TC
SHC
TC
SHC
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
4.01
3.12
4.13
3.57
3.79
2.79
3.91
3.20
3.58
2.48
3.69
2.85
6. Capacity table