[AL. 0F0_Tough drive warning]

• The tough drive function was activated.
[AL. 0F0.1_Instantaneous power failure tough drive warning]
Cause
1.
The voltage of the control circuit power supply
has dropped.
[AL. 0F0.3_Vibration tough drive warning]
Cause
1.
The setting value of the machine resonance
suppression filter was changed due to a
machine resonance.
1 SERVO AMPLIFIER TROUBLESHOOTING
86
1.3 Handling methods for alarms/warnings
Check/action method
Page 13 [AL. 010.1_Voltage drop in the control circuit power]
Check/action method
Set the machine resonance suppression filter. Check the machine status for
loose screws or others.
Model
[A]
[G]
[WG]
Model