Display
5.12.2 Reset to factory settings
All special parameters saved by the user will be overwritten by the factory settings!
Operating
element
099-004846-EW501
8.01.2014
Setting/selection
Predefined execution of the pulsed arc welding process in the PA program
1 =
If the superPuls and welding process switching functions are available and
activated, the pulsed arc welding process is always executed in the main
program PA (ex factory).
0 =
Predefined execution of the pulsed arc welding process in the PA program is
disabled.
Predefined absolute value for relative programs
Start program (P
), down-slope program (P
START
relative to the main program (P
0 =
Relative parameter setting (ex factory)
1 =
Absolute parameter setting
Action
Result
Switch off welding machine
Keep the button pressed
Switch on welding machine
Release the button, wait about 3 seconds
Switch off welding machine and restart in order to put the changes into
effect
Design and function
Special parameters (advanced settings)
) and end program (P
B
) or in an absolute manner, as desired.
A
NOTE
) can be set
END
67