INTRODUCTION Welcome VISAIR CABINETS INTRODUCTION Future Welcome to the world of FPG! Our products are designed and engineered to Products give you the optimal performance that you deserve with innovative visual Group (FPG) merchandising appeal. We are confident that you will be delighted with your state of the art inline food service cabinet, and that it will become a valued appliance in your store.
• Fair wear and tear. Assessment The liability under this warranty is dependent on an assessment by FPG, to determine the defect in workmanship or materials. Time Limit FPG does not guarantee that any service to be performed under this warranty will be carried out within any particular time limit.
OPERATION Cabinet Layout VISAIR CABINETS OPERATION Self Service These open front cabinets are designed for the display Cabinets of hot pre-cooked food. Some models have rear loading doors. The cabinets are fitted with two or three shelves, and items may also be placed on the base tray. Radiant heating elements are incorporated into the ceiling and shelves, to achieve uniform product temperatures.
Preparation VISAIR CABINETS OPERATION Shelf Location The shelf positions can be adjusted by only a small and Ticketing amount, because of the cables required for heating and lighting. The heat output of the radiant elements is factory set for even temperature distribution with the shelves in these positions.
Operating Routines VISAIR CABINETS OPERATION Operating The cabinet is designed to maintain products at a temperature above 65C. Environment The heating system is designed to maintain this temperature, provided the cabinet is not located in a draughty location. Do not place electric fans close to the open front of the cabinet. Temperature Since the cabinet uses infra-red radiation (IR), to maintain the temperature of Monitoring...
TROUBLE SHOOTING Element Failure In the event of one or more infrared elements failing, the Dixell controller will display the alarm “EA” along with an audible alarm sound. Alarm Display Turn the cabinet off and remove all food from the cabinet. Call for service. FAULT POSSIBLE CAUSE REMEDY...
CLEANING Cautions VISAIR CABINETS CLEANING Power ALWAYS TURN THE POWER SUPPLY OFF BEFORE CLEANING. Water THIS UNIT IS NOT WATERPROOF. DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THIS CABINET. Exterior VISAIR CABINETS CLEANING Metal Surfaces Stainless steel or aluminium surfaces should be cleaned with hot soapy water.
Interior cont. VISAIR CABINETS - CLEANING Shelves The shelves can normally be cleaned in place, but can be removed from the cabinet for more thorough cleaning. Unplug the heating and lighting connectors, from each side of the shelf, lift the shelf upwards and pull it forward to disengage from the pillars.
INSTALLATION Regulations VISAIR CABINETS INSTALLATION Compliance It is very important that your inline food cabinet is installed correctly and that the with Local operation is correct before use. Installation must comply with local electrical, Requirements health & safety and hygiene requirements. Setting Up VISAIR CABINETS INSTALLATION...
Location VISAIR CABINETS INSTALLATION Operating The cabinet is designed to maintain products at a temperature above 65C. Environment The heating system is designed to maintain this temperature, providing the cabinet is not located in a draughty location. Do not place electric fans close to the open front of the cabinet. Place A minimum space of 50mm should be left behind the cabinet, to allow air to circulate through the vents and fan.
SERVICING Control Gear VISAIR CABINETS SERVICING Caution DO NOT service lights without isolating the cabinet at the main switch or unplugging it from the wall. Access to Pull on the lower edge of the base Control Gear panel to disengage the magnetic catches.
Cooling Fans VISAIR CABINETS SERVICING Requirement Not all models require cooling fans. Fan Operation The fans cool the cabinet top, by circulating air drawn via the cavity behind the insulated back of the cabinet. If the top of the cabinet becomes very hot, the fan or its power supply may have failed.
Lamp and Element Replacement VISAIR CABINETS SERVICING Note The details of the shelf assemblies and connectors vary with cabinet model. Top Light or The complete top Element element assembly Replacement can be hinged downwards, after removing the fixing screws. Elements and lighting strips can then be replaced.
Dixell Controller VISAIR CABINETS SERVICING Temperature Model XR20CX is a microprocessor based Regulator controller. XR20CX In this application it is configured as a heating controller, and unwanted functions are disabled. XR20CX Key FUNCTION Functions To display target set point; in programming mode it selects a parameter or confirm an operation (UP): To see the max.
SPECIFICATIONS Mechanical VISAIR CABINETS SPECIFICATIONS CABINET MODEL IN-VH06 A001/3 IN-VH09 A001/3 IN-VH12 (A002/4/6&8)* IN-VH18 IN-VH24 (A004)* (A002/4) * (A002/4) * 1481mm 1481mm 1481mm (1900mm)* 1481 mm 1481mm(1900mm)* Height 659 mm 901 mm 1267 mm 1865 mm 2408 mm Width 736 mm 736 mm 736 mm 736 mm...
Temperature Controller Settings VISAIR CABINETS SPECIFICATIONS Dixell XR20CX Settings Set point degC Differential degC Minimum Set Point degC Maximum Set Point degC First probe Calibration degC Kind of Action Heating cL, oP Digital Input Polarity EAL, bAL, PAL, dor, Digital Input Configuration dEF, AUS, Htr, ES Digital Input Alarm Delay Measurement Units...
23°C Ambient with 65% RH Improvements VISAIR CABINETS SPECIFICATIONS On-going FPG reserves the right to change specifications and construction, as part of on- Development going product improvement. Part No. 24895 Rev. Y March 2018 - 22 - Visair Heated Cabinets...
When ordering spare parts, it is important to quote the Serial Number printed on Number the identification label. This will enable FPG to trace details of the build specification of your particular cabinet and hence ensure that spare parts are fully compatible.
Page 30
Spare Parts continued End Glass LH & RH (600/900/1200/1800/2400 cabinets) 68734 End Glass LH (Custom flat sided cabinets) 68270 End Glass RH (Custom flat sided cabinets) 68278 Glass rear door assembly (VH12 A006) 72100 Glass Up-stand 600 26288 Glass Up-stand 900 26390 Glass Up-stand 1200 24871...