Installation - Graco Bulldog Hydra-Cat Series Instructions And Parts List

Fixed ratio proportioning pumps
Table of Contents

Advertisement

Bare Pumps
Bare pumps are available for those installations which
require a highly customized system. For a safe and
efficient system, Graco recommends that the air and
fluid components supplied with the Wall Mount and
Cart Mount models also be used in customized
systems. Refer to the Parts Drawings starting on page
28 for part numbers. In addition, the accessories
shown in the Typical Installation drawings and
discussed in the following pages of this manual should
be used.
Be sure all accessories are sized properly for the air
and fluid requirements of your system.
Read all instructions in the Installation section for
further details.

Installation

NOTES:
1. Models with three displacement pumps always use
the two outer displacement pumps to supply the
resin and the middle displacement pump to supply
the hardener.
2. Label all pumps, hoses, fluid regulators, etc. to
indicate whether they are for the resin side or
hardener side of the system.
Mounting the Pump
Mount the pump to suit your installation. The bare
pump can be mounted on a wall bracket or on a cart.
See Dimensions on page 43. The Bulldog pump and
accessories weigh approximately 115 lb (52 kg). The
pump stand and accessories weigh 55 lb (25 kg).
For a wall mount, be sure the bracket and wall are
strong enough to support the pump, accessories,
plumbing and stress caused by pump operation.
Locate the bracket about 5 ft (1.5 m) above the floor.
308225