Kenwood NX-800 Service Manual page 88

Uhf digital transceiver
Hide thumbs Also See for NX-800:
Table of Contents

Advertisement

NX-800
Item
Panel tuning mode
8. QT
1) Adj item: [An QT]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw QT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
9. DQT
1) Adj item: [An DQT]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw DQT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
10. LTR
1) Adj item: [An LTR]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw LTR]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
88
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [QT Devia-
Deviation
tion (Narrow)]
meter
Deviation meter
Oscilloscope
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [LTR De-
viation (Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [LTR De-
viation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
ANT
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
0.30~0.40kHz
tuning
followings.
mode]
513 (Reference
[ ],[ ]
value)
[PC test
mode]
[ ],[ ]
0.70~0.80kHz
Write the value as
0.30~0.40kHz
followings.
430 (Reference
value)
0.70~0.80kHz
Write the value as
0.70~0.80kHz
followings.
465 (Reference
value)
0.95~1.05kHz
Remarks