Kenwood NX-800 Service Manual page 80

Uhf digital transceiver
Hide thumbs Also See for NX-800:
Table of Contents

Advertisement

NX-800
Item
Panel tuning mode
4. RTC
1) Adj item: [RTC]
oscillation
Adjust: [✳✳✳]
frequency
adjust
5. Frequency
* The Frequency
adjust
adjustment can be
performed only in
PC test mode.
80
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [RTC
(Real-time clock)]
1) Adj item: [Frequen-
SSG
cy]
2) CH-Sig: 1-1
SSG output:
–20dBm (CW (with-
out modulation))
Caution:
Perform the frequency
adjustment under the
following conditions.
• Temperature range
of +23˚C to +27˚C
(+73.4˚F to +80.6˚F).
(The temperature is
displayed on the Fre-
quency adjustment
screen of the KPG-
111D(C) and the
LCD of the trans-
ceiver.)
• Use an accuracy
of 0.001ppm for
the SSG. (Use a
standard oscillator if
necessary.)
Measurement
Test-
Unit Terminal Unit
ANT
Adjustment
Specifi cations /
Parts
Method
[ ]
[Panel tuning mode]
Adjustment of the
Press [ ] key. After
transceiver's inter-
automatic adjust-
nal clock.
ment adjusted value
is displayed on LCD.
Press [ ] key to
store the adjust-
ment value.
[PC test mode]
Press [Start] button
of "Auto Tuning".
Press [Apply] button
to store the adjust-
ment value after the
automatic adjust-
ment was fi nished.
[ ]
[PC test mode]
[PC test mode]
Press [Start] button
"IF20" value =
of "Auto Tuning".
Within 0±12 digits.
Press [Apply] button
The value of "IF20"
to store the adjust-
will become around
ment value after the
"0" after the adjust-
automatic adjust-
ment was fi nished.
ment was fi nished.
Frequency is adjust-
ed under receiving
condition with SSG.
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-800 e

Table of Contents