Kenwood NX-800 Service Manual page 96

Uhf digital transceiver
Hide thumbs Also See for NX-800:
Table of Contents

Advertisement

NX-800
Item
Panel tuning mode
[NXDN
1) Adj item: [Nv RRSSI]
Very
Adjust: [✳✳✳]
Narrow]
2) Adj item:
[NvL RRSSI]→
[NvL' RRSSI]→
[NvC RRSSI]→
[NvH' RRSSI]→
[NvH RRSSI]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz,
Dev: ±1.5kHz)
*5: Because "RSSI reference adjust" of NXDN Narrow is adjusted by adjusting "RSSI reference adjust [Analog Narrow]", it is not necessary to
adjust "RSSI reference adjust" of NXDN Narrow.
5. Open
1) Adj item: [An SQL]
Squelch
Adjust: [✳✳✳]
adjust *6
2) Adj item:
(Squelch
[AnL SQL]→
level 5
[AnL' SQL]→
adjust)
[AnC SQL]→
[AnH' SQL]→
[Analog
[AnH SQL]
Narrow]
SSG output: 12dB
SINAD level +1dB
(MOD: 1kHz,
Dev: ±1.5kHz)
[Analog
1) Adj item: [Aw SQL]
Wide]
Adjust: [✳✳✳]
2) Adj item:
[AwL SQL]→
[AwL' SQL]→
[AwC SQL]→
[AwH' SQL]→
[AwH SQL]
SSG output: 12dB
SINAD level +1dB
(MOD: 1kHz,
Dev: ±3kHz)
[NXDN
1) Adj item: [Nv SQL]
Very
Adjust: [✳✳✳]
Narrow]
2) Adj item:
[NvL SQL]→
[NvL' SQL]→
[NvC SQL]→
[NvH' SQL]→
[NvH SQL]
SSG output: 12dB
SINAD level –2dB
(MOD: non)
*6: Because "Squelch (Open) adjust" of NXDN Narrow is adjusted by adjusting "Squelch (Open) adjust [Analog Narrow]", it is not necessary to
adjust "Squelch (Open) adjust" of NXDN Narrow.
96
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [RSSI Ref-
SSG
erence (Very Narrow)]
AF VTVM
2) Adj item: [Low],
Oscilloscope
[Low'], [Center],
Distortion
[High'], [High]
meter
SSG output: 12dB
Dummy
SINAD level –3dB
load
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item: [Open
SSG
Squelch (Narrow)]
AF VTVM
2) Adj item: [Low],
Oscillo-
[Low'], [Center],
scope
[High'], [High]
Distortion
SSG output: 12dB
meter
SINAD level +1dB
Dummy
(MOD: 1kHz,
load
Dev: ±1.5kHz)
1) Adj item: [Open
Squelch (Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level +1dB
(MOD: 1kHz,
Dev: ±3kHz)
1) Adj item: [Open
Squelch (Very Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output: 12dB
SINAD level –2dB
(MOD: non)
Measurement
Test-
Unit Terminal Unit
ANT
Ext.SP
connec-
tor
ANT
Ext.SP
connec-
tor
Adjustment
Specifi cations /
Parts
Method
[Panel
[Panel tuning mode]
Adjust with the ana-
tuning
After input signal
log signal.
mode]
from SSG, press
[ ],[ ]
[ ] key to store the
adjustment value.
[PC test
mode]
[PC test mode]
[ ],[ ]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
[Panel
[Panel tuning mode]
"Open Squelch"
tuning
After input signal
will not be adjusted
mode]
from SSG, press
correctly if MOD
[ ],[ ]
[ ] key to store the
and Deviation are
adjustment value.
wrong.
[PC test
mode]
[PC test mode]
[ ],[ ]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Adjust with the ana-
log signal.
This item is ad-
justed under the
condition that MOD
is "non" due to the
circuit confi gura-
tion.
Remarks