Description of the ProfiNet interface

Positioning resolution of 1 µm (independent from the real sensor resolution), max. 0x989680 (10.000.000) is
used. The command position is limited by the parameter SYSRANGE.
The command speed is interpreted in percentage of the programmed speed or of the output signal. The
value of 0x3fff corresponds with 100 % speed.
The module is controlled with a control word consisting of following bits:
Bit name
ENABLE
START
HAND:A
HAND:B
DC_F-POS
DC_ACTIVE
DC_FREEZE
SC
DIRECT
PARAMODE
PARAVALID
LIVEBIT
Setting of the bits (signal 1) activates the relating function.
Further demands like command position, speed and parameterizing.
Byte notation
COMMAND POSITION
COMMAND SPEED
PARAMETER VALUE
PARAMETER ADRESS
Page 43 of 62
Description of the bit
General activation of the axis. Malfunction monitoring and output signal get
activated (in combination with the hardware enable)
Start signal for positioning. The actual transmitted command value is taken over
and the output will be controlled relating to the parameterization.
Manual mode. The axis is driven with the preset speed (parameter with the
same name). This mode can only be used when ENABLE is available and the
START comand is not set.
Manual mode, see HAND:A. Two parameters are available for this mode for
example in order to preparameterize manual driving in both directions.
Fine positioning function (look at chapter 5.6.6).
Drift compensation function (look at chapter 5.6.6).
Storing of the drift compensation value as offset for the output.
Synchronous control. In synchronous run the preset values for axis 2 are not
active. The system is driven by the demand values of axis 1.
In direct mode new command positions are taken over directly from the
controller while START signal is available. In normal mode the START signal
has to be reset and set again for getting a new command position into the
module.
Provides parameterizing the controller via Fieldbus instead of the USB port
(chapter 7.8).
Transmitting new parameter setting (at rising edge).
Here the controller can provide an alternating input signal in order to monitor the
funtioning of the bus connection. It will be returned by the output
"LIVEBIT_OUT".
Description of the byte
With the resolution of 1 µm the position which will be driven to after setting
START is preset.
Sets the maximum possible speed of the axis. 3FFF allows 100%, if the
parameterization provides it. This limitation is also responsible for the manual
mode.
New value for a parameter to be changed via the fieldbus (for possible vlaues
and ranges look at chapter 7.8).
Adress of the parameter to be changed (look at chapter 7.8).
POS-124-U-PFN-2030