W.E.ST. POS-124-U-PFN Technical Documentation Manual page 20

Two axes positioning and synchronisation control module with integrated profinet io interface and ssi sensor interface
Hide thumbs Also See for POS-124-U-PFN:
Table of Contents

Advertisement

Group
Command
Synchronous run (MODE = SYNC)
SYNCMODE
SYNCWIN
SYNC:P
SYNC:V0
SYNC:T1
Output signal adaption (MODE = OUTPUT)
EOUT_1
MIN_1:A
MIN_1:B
MAX_1:A
MAX_1:B
TRIGGER_1
OFFSET_1
SIGNAL_1:U
EOUT_2
MIN_2:A
MIN_2:B
MAX_2:A
MAX_2:B
TRIGGER_2
OFFSET_2
SIGNAL_2:U
Fine positioning / drift compensation
DC_1:AV
DC_1:DV
DC_1:I
DC_1:CR
DC_2:AV
DC_2:DV
DC_2:I
DC_2:CR
Special commands (TERMINAL)
AINMODE
AIN_1:X
AIN_2:X
Page 20 of 62
Default
Unit
MS
-
5000
µm
50
mm
10
s
-1
80
ms
0
0.01 %
0
0.01 %
0
0.01 %
10000
0.01 %
10000
0.01 %
200
0.01 %
0
0.01 %
U+-10
-
0
0.01 %
0
0.01 %
0
0.01 %
10000
0.01 %
10000
0.01 %
200
0.01 %
0
0.01 %
U+-10
-
0
0.01 %
0
0.01 %
2000
ms
500
0.01 %
0
0.01 %
0
0.01 %
2000
ms
500
0.01 %
EASY
-
A:
1000
-
B:
1000
-
C:
0
0.01 %
X:
V
-
POS-124-U-PFN-2030
Description
Synchronization mode
Synchronization error window
P gain (deceleration stroke, SDD)
Loop gain (NC)
Time constant
Output signal if not ready
Deadband compensation
Output scaling
Deadband compensation trigger point
Offset value for the output
Type and polarity of output signals
Output signal if not ready
Deadband compensation
Output scaling
Deadband compensation trigger point
Offset value for the output
Type and polarity of output signals
Point of activation
Point of deactivation
Time constant of the integrator function
Limit of the control range
Point of activation
Point of deactivation
Time constant of the integrator function
Limit of the control range
Input scaling mode
Free scaling of the analogue inputs (MATH). Re-
places SIGNAL, N_RANGE and OFFSET.
Please contact W.E.St..
23.08.2016

Advertisement

Table of Contents
loading

Related Products for W.E.ST. POS-124-U-PFN

This manual is also suitable for:

Pos-124-u-etcPos-124-u-pdpPos-124-u-pfn-2030

Table of Contents