Ssi:errbit (Position Of The "Out Of Range" Bit); Sys_Range (Working Stroke); N_Range:x (Nominal Range Of The Sensor); Offset (Sensor Zero Correction) - W.E.ST. POS-124-U-PFN Technical Documentation Manual

Two axes positioning and synchronisation control module with integrated profinet io interface and ssi sensor interface
Hide thumbs Also See for POS-124-U-PFN:
Table of Contents

Advertisement

SSI:ERRBIT (Position of the "out of range" bit)

Command
SSI:ERRBIT
The position of the error bit will be defined by this parameter.
The appropriate data can be found in the sensor data sheet. In case of no described error bit, the default
value is 0 (deactivation of the monitoring).

SYS_RANGE (Working stroke)

Command
SYS_RANGE_1
SYS_RANGE_2
This command defines the full stroke, which corresponds to 100 % of the input signal. If the demand is set
incorrectly, this leads to incorrect system settings, and the dependent parameters such as speed and gain
cannot be calculated correctly.

N_RANGE:X (Nominal range of the sensor)

Command
N_RANGE_1:X
N_RANGE_2:X
N_RANGE (nominal range or nominal stroke) is used to define the length of the sensor. This value should be
always higher than SYS_RANGE. The control parameter cannot be calculated correctly in case of wrong val-
ues.

OFFSET (Sensor zero correction)

Command
OFFSET_1:X
OFFSET_2:X
This parameter is entered in 0.01% units.
The offset value is added to the control element signal at the output and limited to SYS_RANGE.
Page 24 of 62
Parameter
x
x= 8... 31
Parameters
x
x= 10... 10000
x
x= 10... 10000
Parameter
x
x= 10... 10000
x
Parameter
x
x= -100000...
100000
x
POS-124-U-PFN-2030
Unit
Group
-
INPUT
Unit
Group
mm
INPUT
mm
Unit
Group
mm
INPUT
Unit
Group
µm
INPUT
23.08.2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pos-124-u-etcPos-124-u-pdpPos-124-u-pfn-2030