Ssi:res (Signal Resolution); Ssi:bits (Number Of Bits); Ssi:code (Signal Coding); Ssi:pol (Direction Of The Sensor Signal) - W.E.ST. POS-124-U-PFN Technical Documentation Manual

Two axes positioning and synchronisation control module with integrated profinet io interface and ssi sensor interface
Hide thumbs Also See for POS-124-U-PFN:
Table of Contents

Advertisement

SSI:RES (Signal resolution)

Command
SSI:RES
This command defines the signal resolution
ters or 0.01 micron). If the sensor has one-micron resolution, the value must be set to 100. This makes it
possible to scale rotational sensors.
Take the data from the sensor data sheet.

SSI:BITS (Number of bits)

Command
SSI:BITS
With this command the number of data bits can be set.
Take the data from the sensor data sheet.

SSI:CODE (Signal coding)

Command
SSI:CODE
With this command the signal coding can be set. Take the data from the sensor data sheet.

SSI:POL (Direction of the sensor signal)

Command
SSI:POL1
SSI:POL2
To reverse the working direction of the sensor, with this command, the polarity can be changed.
3
The internal resolution of the controller is 1 µm. The sensor with better resolution should not be used without consulting
with the manufacturer.
Page 23 of 62
Parameters
X
x= 100... 10000
3
of the sensor. Data entry has a resolution of 10 nm (nanome-
Parameters
X
x= 8... 31
Parameters
X
x= GRAY|BIN
Parameters
X
x= +|-
X
POS-124-U-PFN-2030
Unit
Group
0.01 µm
INPUT
Unit
Group
-
INPUT
Unit
Group
-
INPUT
Unit
Group
-
INPUT
23.08.2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pos-124-u-etcPos-124-u-pdpPos-124-u-pfn-2030

Table of Contents