Circuit Diagram - W.E.ST. POS-124-U-PFN Technical Documentation Manual

Two axes positioning and synchronisation control module with integrated profinet io interface and ssi sensor interface
Hide thumbs Also See for POS-124-U-PFN:
Table of Contents

Advertisement

4.3

Circuit diagram

ProfiNet
ProfiNet
ANA Feedback
13
0..10V
Position 1
4..20mA
11
0 V
0 V
SSI Feedback
Position 1
33
24 V
34
0 V
37
CLK+
38
CLK-
39
DATA+
40
DATA-
ANA Feedback
14
0..10V
Position 2
4..20mA
11
0 V
0 V
SSI Feedback
Position 2
47
24 V
48
0 V
41
CLK+
42
CLK-
43
DATA+
44
DATA-
8
Enable
Page 15 of 62
v1
Speed
via Fieldbus
VMODE = NC
wa1
w1
Profile
Position
via Fieldbus
Generator
VMODE = SDD
Input
Scaling
INPX = ANA
SSI
Sensor
INPX = SSI
Input
Scaling
INPX = ANA
SSI
Sensor
INPX = SSI
Control program
24 V input
Support
Diagnostics
- Real time function
- Remote control
- communication
- Process data
- Error handling
- Error information
POS-124-U-PFN-2030
POS-124-U-PFN
Internal Power
Control
e1
Function
Output
Adaptation
SDD or NC
-
mode
AXIS 1
x1
x1
Synchronous
Controller
MS or AV
x2
AXIS 2
Send to the Fieldbus
- Status informations
- System errors
- command position
Serial
- feedback position
57600 Bd
8N1
USB
USB Type B
35
31
3
24 V
DC
DC
4
0 V
32
36
Differentialinput
15
Output: A
u1
16
Output: B
12
Current mode: 4... 20 mA
PIN 15 = +, PIN 12 = GND
Enable Sync.
via Fieldbus
Differentialinput
19
Output: A
u2
20
Output: B
18
Current mode: 4... 20 mA
PIN 19 = +, PIN 18 = GND
1
Ready
24 V output
PE via DIN-RAIL
24 V
PELV
0 V
23.08.2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pos-124-u-etcPos-124-u-pdpPos-124-u-pfn-2030

Table of Contents