2.17 Built In TCP/IP Xport as Converter

Located under the "Ethernet Connection" as written on the overlay connections label

Figure 12 - Lantronix Xport

(NB make note of the MAC address written on the device e.g. 00-20-4A-CC-F9-AF as this
will be useful when configuring the IP Address)
Having connected the I/P Ethernet to the TCP/IP Xport device on the EXcel
You can connect additional EX series controllers with 4 wire RS485 communications (2
wire RS485 is not supported in this instance) using the following table:
Connections from the I/P
connected EXcel
ACU chassis
Below is an example of multiple ACU's of differing TDSi types on an Ethernet and then
converted to RS485 4 wire protocol.
RS485-connected to other
EX series ACU
4
1
2
3
4
EXcel4 Controller
1
2
3
4
ACU chassis
4
Function
RS485A TX
RS485B TX
RS485A RX
RS485B RX
Protective screen