2.8 Door sensors

Most door sensors have contacts that are closed when the door is closed. If fitting one
where the opposite is true, make the appropriate selection in EXgarde.
If no door sensor is to be fitted then the factory fitted link should be left in place otherwise
the on-board buzzer will start to sound shortly after powering up EXcel 4 (typically 15
seconds after as this is the onboard local alarm for door ajar feature
EXcel terminal
22
23
36
37
49
50
55
56

2.9 Egress buttons (push to exit)

Use a voltage free contact, simply by shorting the connection between "Egress 0V" and
"Egress input" will activate the relay and its associated door.
EXcel terminal
23
24
37
38
50
51
56
57

2.10 Inputs

EXcel
terminal
36
37
38
49
50
51
55
56
57
Function
Door 1 Door sense input
Door 1 Door sense 0V
Door 2 Door sense
Door 2 Door sense 0V
Door 3 Door sense input
Door 3 Door sense 0V
Door 4 Door sense
Door 4 Door sense 0V
Function
Door 1 Egress 0V
Door 1 Egress input
Door 2 Egress 0V
Door 2 Egress input
Door 3 Egress 0V
Door 3 Egress input
Door 4 Egress 0V
Door 4 Egress input
Function
Input 3
0V (for Inputs 3 & 4)
Input 4
Input 5
0V (For inputs 5 & 6)
Input 6
Input 7
0V (For inputs 7 & 8)
Input 8
EXcel4 Controller
Only available in the
following
configurations
1 Door
1 or 2 Door
1, 2 or 3 Door
Page 17