Make a start and stop with terminals (External operation)
3.5.4
Changing the output frequency (60Hz, initial value) at the maximum voltage input
(5V, initial value)
< How to change the maximum frequency>
Changing
When you want to use the 0 to 5VDC input frequency setting potentiometer to change the frequency at 5V from 60Hz (initial
example
value) to 50Hz, make adjustment to output "50Hz" at 5V voltage input. Set "50Hz" in Pr. 125.
1.
Turn
until "
2.
Press
to show the present set value
"
" (60.00Hz).
3.
Turn
to change the set value to
"
"(50.00Hz).
4.
Press
to set.
5.
Mode/monitor check
Press
twice to choose the monitor/
frequency monitor.
6.
To check the setting, turn the start switch (STF
or STR) ON and input 5V (turn the
potentiometer clockwise slowly to full). (Refer
to operation 2 to 5 of the section 3.5.3)
REMARKS
To change the value to 120Hz or more, the maximum frequency must be set to 120Hz or more.
The frequency meter (indicator) connected across terminals FM-SD does not indicate exactly 50Hz ... Why?
The frequency meter can be adjusted using calibration parameter C0 FM terminal calibration. (
Instruction Manual (Applied)).
Use calibration parameter C2 to set frequency at 0V and
calibration parameter C0 to adjust the indicator.
(
Refer to Chapter 4 of the Instruction Manual (Applied)).
As other adjustment methods of frequency setting voltage gain, there are methods to adjust with a voltage applied to across
terminals 2-5 and adjust at any point without a voltage applied. (
method of calibration parameter C4.)
68
Operation
" (Pr. 125) appears.
Flicker...50Hz output at 5V input complete!!
60Hz
Bias
C2 (Pr. 902)
Refer to the Instruction Manual (Applied) for the setting
Display
Refer to Chapter 4 of the
Initial value
0
100%
Frequency
0
5V
setting signal
0
10V
C3 (Pr. 902)
C4 (Pr. 903)
Gain
Pr. 125