Parameter list
Parameter
Function
Motor excitation
82
current
Rated motor
83
voltage
Rated motor
84
frequency
Motor constant
90
(R1)
Auto tuning
96
setting/status
84
Incre-
Initial
Name
ments
Value
0.01A
9999
200V/
0.1V
400V ∗
0.01Hz
60Hz
0.001Ω
9999
1
0
Range
Description
Set motor excitation current (no load
0 to 500A
current)
Uses the Mitsubishi motor (SF-JR, SF-HR,
9999
SF-JRCA, SF-HRCA) constants
Rated motor voltage (V).
0 to 1000V
* The initial value differs according to the
voltage class. (100V, 200V class/400V class)
10 to
Rated motor frequency (Hz).
120Hz
Tuning data (The value measured by
0 to 50Ω
offline auto tuning is automatically set.)
Use constants of the Mitsubishi motor (SF-
9999
JR, SF-HR, SF-JRCA, SF-HRCA)
0
Offline auto tuning is not performed
For General-purpose magnetic flux vector
control
11
Offline auto tuning is performed without
motor running(motor constant (R1) only)
Offline auto tuning for V/F control
(automatic restart after instantaneous
power failure (with frequency search))
21
(
Refer to Chapter 4 of the Instruction
Manual (Applied))
×
×
×