GEZE hold-open system FA GC 150 Contents Symbols and illustrations ...........................4 Notes ..................................4 Installation and electrical connection of the hold-open system ....................4 Installation of the lintel-mounted smoke switch..........................5 Protecting a smoke switch from soiling ..............................5 Disposal ..........................................5 Hold-open system FA GC 150 ...........................6 Function ..........................................6...
Page 3
GEZE hold-open system FA GC 150 Wireless input module GC 175 ................................36 5.5.1 Manual trigger switch UTA......................................37 5.5.2 Contact to the fire alarm system ....................................37 5.5.3 Contact of the fire alarm system and manual trigger switch UTA .......................38 Alarm output ........................................ 38 Mutual triggering of two hold-open systems ..........................
Symbols and illustrations GEZE hold-open system FA GC 150 Symbols and illustrations Warning notices Warning notices are used in these instructions to warn you of property damage and personal injury. Always read and observe these warning notices. Observe all the measures that are marked with the warning symbol and warning word.
Please dispose of batteries at a municipal collection point or in store. Batteries obtained from us can be returned to us by mail. The address is: GEZE GmbH, Incoming Goods, Reinhold-Vöster-Str. 21-29, 71229 Leonberg/Germany. Batteries which contain harm-...
Hold-open system FA GC 150 GEZE hold-open system FA GC 150 Hold-open system FA GC 150 3. 1 Function Directly after a fire or smoke protection door has been opened, it is closed again by the fitted door closer. This self-closing characteristic is cancelled in a controlled way by the hold-open system, so that a fire or smoke protec- tion door can remain open permanently.
GEZE hold-open system FA GC 150 Hold-open system FA GC 150 Hold-open system with separate smoke control unit RSZ6 The hold-open system RSZ6 comprises: à Energy supply (1) à Power supply RSZ6 à Lintel-mounted smoke switch with trigger mechanism (1) à...
Hold-open system FA GC 150 GEZE hold-open system FA GC 150 Automatic door drives à TSA 160 NT F* hydraulic swing door drive à TSA 160 NT F-IS* hydraulic swing door drive, 2-leaf with integrated mechanical door closing sequence à Slimdrive EMD-F* electromechanical swing door drive à...
GEZE hold-open system FA GC 150 Hold-open system FA GC 150 Classification in accordance with EN 14637 Hold-open system No. 1 Class 3 Application class Frequent use by the general public and other persons with little incentive to take care No.
Hold-open system FA GC 150 GEZE hold-open system FA GC 150 Usually there must be at least one ceiling-mounted detector - i.e. one pair of detectors - fitted in the rooms adjacent to the smoke opening – and at least...
Page 11
GEZE hold-open system FA GC 150 Hold-open system FA GC 150 à TS 4000 R, TS 4000 R-IS à TS 5000 R, TS 5000 R-ISM, TS 5000 R-ISM/G, TS 5000 R-ISM/S, TS 5000 R-ISM/0 can be triggered by hand by closing the door leaves manually.
Technical data GEZE hold-open system FA GC 150 Technical data 4. 1 Hold-open system FA GC 150 Protection rating (according to DIN EN 61140) TS 4000 R, TS 4000 RFS RSZ6 (if automatic swing door drives TS 4000 R-IS, TS 5000 RFS KB...
GEZE hold-open system FA GC 150 Technical data Lintel-mounted smoke switch GC 151 Lintel-mounted smoke switch GC 151 ID 142250 Functional principle Scatter light, adaption of the alarm threshold, no alarm saving (self-reset- ting as soon as there is no longer any smoke in the measuring chamber) Input voltage 24 V ±...
Technical data GEZE hold-open system FA GC 150 State / fault Alarm output Hold-open output KL1: 3-4 / KL3: 1-2 Voltage-free AL_NC AL_COM AL_NO Normal operation green 24 V Soiling (warning) 24 V The lintel-mounted smoke switch should be replaced.
GEZE hold-open system FA GC 150 Technical data Frequency range 868.15 MHz to 869.85 MHz Range 10 m (100 m in space) Number of frequency channels Modulation technique FSK (frequency shift keying) Radiated power 5 dBm (3 mW) LED2 LED2 LED11...LED16...
Page 16
Technical data GEZE hold-open system FA GC 150 Wireless module GC 171 Lintel-mounted smoke switch GC 151 (“operating” mode) Wireless State / Wireless device LED 1x Status LEDs Alarm output Hold-open connec- fault LEDs output tion KL1: 3-4 / KL3: 1-2 flashes green Æ...
Page 17
GEZE hold-open system FA GC 150 Technical data General fault The wireless module GC 171 signals “general fault” if à no wireless connection is set up, à the set-up switch is in the ON position with GC 172, GC 173 or GC 175, à...
Technical data GEZE hold-open system FA GC 150 4.5.2 Set up wireless connection” mode Set up a new wireless connection In the “set up wireless connection” mode, new wireless connections can be set up to new wireless devices GC 172, GC 173 or GC 175. A maximum of 6 wireless connections can be set up.
Page 19
GEZE hold-open system FA GC 150 Technical data Wireless ceiling-mounted detector GC 172 or GC 173 The LEDs of the new wireless ceiling-mounted detector flash green twice first, then light up yellow for one se- red four times. As soon as the LED cond and then flash goes out after that, the connection can be set up.
Technical data GEZE hold-open system FA GC 150 Löschen aller Funkverbindungen Im Modus „Funkverbindung einrichten“ können alle bereits eingerichteten Funkverbindungen gelöscht werden. 1. Nach dem Einschalten der Versorgungsspannung befin- det sich das Funkmodul GC 171 im Modus „Betrieb“. Alle SW1x Funkgeräteschalter SW1x befinden sich in Position OFF.
Technical data Detector test Alarm triggering - using test magnet near the magnetic sensor (GEZE logo) - using test aerosol The detector test using a test magnet tests the electrical components. The detector test which forms part of the regular testing of the hold- open system must be carried out using a test aerosol (see 6.2.2).
GC 150 B Fig. 4.7.3 Breaking point (see Chapter 5.2) LED for displaying state Magnetic sensor for testing (behind the GEZE logo) Ceiling-mounted smoke detector ORS 142 Ceiling-mounted smoke detector kit ORS 142 with ID 141715 - 2 x smoke detector ORS 142...
Page 23
GEZE hold-open system FA GC 150 Technical data Functional principle - Smoke detection Scatter light, adaption of alarm threshold, self-resetting hermal sensor 70°C ±5 Input voltage 24 V DC Input current Maximum of 22 mA Installation position Ceiling mounting IP rating...
Ceiling mounting Detector test Alarm actuation - using test magnet near the magnetic sensor (GEZE logo) - using test aerosol The detector test using a test magnet tests the electrical components. The detector test which forms part of the regular testing of the hold-open system must be carried out using a test aerosol (see 6.2.2).
GEZE hold-open system FA GC 150 Technical data 4.9. 1 Signalling The LEDs of the wireless ceiling-mounted smoke detector GC 172 indicates various states and events State, event LED for displaying state Switch on flashes 1 x green, then red for approx. 1 min, then green...
FSK (frequency shift keying) Radiated power 5 dBm (3 mW) CR123A CR2032 Fig. 4.10.1 1 Magnetic sensor for testing (behind the GEZE logo) 2 LED for displaying state 3 Set-up switch 4 Sabotage contact 5 Battery compartment 6 Main battery...
GEZE hold-open system FA GC 150 Technical data 4. 1 0.2 Battery replacement The wireless detector signals “Low battery charge” to the wireless module GC 171 if the charge state of the bat- teries is no longer sufficient. Both batteries (main battery and slave battery) always have to be replaced together.
Technical data GEZE hold-open system FA GC 150 Installation position Installation in flush-mounted socket or cavity box Installation in such a way that removing the wireless module and manual trigger switch is only possible after these two assemblies have been dis- connected from one another (e.g.
à The cables must be sufficiently mechanically protected and attached. à Insulate wires that are not used. 5. 1 Mains connection à The GEZE hold-open systems are devices of protection rating I or protection rating II in accordance with DIN EN61140.
Wiring diagram GEZE hold-open system FA GC 150 à Devices of protection rating I are connected using a three core cable NYM-J, 3x1.5 mm The protective earth conductor is connected to the PE terminal. Power supply GC 151 max. Fig. 5.1.1.1 5.
Page 31
GEZE hold-open system FA GC 150 Wiring diagram The resistors for line monitoring and alarm resistance are installed in the relay base GC 150 B. The resistors for line monitoring are located on a PCB inside the relay base. These can be disconnected using a screwdriver as described above.
Page 32
Wiring diagram GEZE hold-open system FA GC 150 Connection of a ceiling-mounted thermal detector GC 153 as a lintel-mounted detector Cover smoke chamber Ceiling-mounted detector as lintel-mounted detector Fig. 5.2.1.5 Connection of a ceiling-mounted thermal detector GC 153 as a lintel-mounted detector and two further...
GEZE hold-open system FA GC 150 Wiring diagram 5.2.2 Ceiling-mounted smoke detector ORS 142 The ceiling-mounted detector ORS 142 is made up of the smoke detector ORS 142 and the base ORS 143 A. Ceiling-mounted smoke detector kit ORS 142 with ID 141715 à...
Wiring diagram GEZE hold-open system FA GC 150 Connect the manual trigger switch as a NO contact. Fig. 5.3.1.1 Several manual trigger switches are connected in parallel. Only connect the 43 kΩ resistor in the last one. Fig. 5.3.1.2 The cable to the first manual trigger switch (UTA) must be laid separately or protected.
GEZE hold-open system FA GC 150 Wiring diagram Potentialfreier Kontakt (BMA) The cable to the potential-free contact (fire-alarm system) must be laid separately or protected. Wireless module GC 171 à Wireless module GC 171, ID 163051 Wireless ceiling-mounted smoke detector GC 172 - ID 159656...
Wiring diagram GEZE hold-open system FA GC 150 5.4.2 Wireless ceiling-mounted detector GC 172 or GC 173 – manual trigger switch or fire alarm contact wired à Manual trigger switch or fire alarm contact are connected as described in Chapter 5.3.
GEZE hold-open system FA GC 150 Wiring diagram 5.5. 1 Manual trigger switch UTA à Manual trigger switch UTA, AS500, ID 116266 Surface-mounted cap, single, AS500, ID 120503 à Note the requirements on the installation of manual trigger switch in Chapter 3.5.
Wiring diagram GEZE hold-open system FA GC 150 5.5.3 Contact of the fire alarm system and manual trigger switch UTA The general construction technique permit requires line monitoring to the potential-free contact of the fire alarm system and to the manual trigger switch.
GEZE hold-open system FA GC 150 Wiring diagram Fig. 5.7.1 Hold-open mechanism à External hold-open mechanisms are connected to KL1 of the lintel-mounted smoke switch (screw-push-terminal). Internal hold-open mechanisms are connected to KL3 of the lintel-mounted smoke switch (system plug-type connection).
Page 40
Wiring diagram GEZE hold-open system FA GC 150 Door closer TS 4000 E-IS Door leaf installation à Connector box with plug-in cable transition, ID 052105 GC 151 Anschlusskasten TS 4000 E-IS Door Active leaf transition Switch closed if active leaf open I=42 mA 24 VDC±15%...
Page 41
GEZE hold-open system FA GC 150 Wiring diagram E-ISM guide rail, E-ISM guide rail Boxer (E-ISM/G no hold-open device in the passive leaf, E-ISM/S no hold-open device in the active leaf) Connection board E-hold-open device for active leaf active leaf 24 VDC±15%...
Page 42
Wiring diagram GEZE hold-open system FA GC 150 Transom installation 24 VDC±15% Res. rip. <20% I=42 mA Fig. 5.8.1.9 Integrated door closer Boxer EFS Boxer EFS 24 VDC±15% Restw. <20% I=80 mA Fig. 5.8.1.10 Floor spring TS 550 NV-E 24 VDC±15% Res.
Page 43
GEZE hold-open system FA GC 150 Wiring diagram Floor spring TS 550 E-IS à Connection PCB, ID 001102 à Terminal box on site Active leaf Passive leaf 24 VDC±1 % 24 VDC±1 % Res. rip. <20% Res. rip. <20% I=100 mA...
Page 44
Wiring diagram GEZE hold-open system FA GC 150 Hydraulic swing door drive TSA 160 NT F*, TSA 160 NT F EN7* Accessories TSA 160 NT F, ID 019654 Follow the wiring diagram for the TSA 160 NT swing door drive.
Page 45
GEZE hold-open system FA GC 150 Wiring diagram Electromechanical swing door drive Slimdrive EMD F* Follow wiring diagram for the Slimdrive EMD swing door drive. Latching Reset action Fig. 5.8.1.17 Electromechanical swing door drive Slimdrive EMD-IS* Follow wiring diagram for the Slimdrive EMD swing door drive.
Page 46
Wiring diagram GEZE hold-open system FA GC 150 Electromechanical swing door drive Powerturn F* Follow wiring diagram for the Powerturn swing door drive. Powerturn F DCU8 DCU801 DCU802 DCU800 Latching Reset action Fig. 5.8.1.19 Electromechanical swing door drive Powerturn F-IS* Follow wiring diagram for the Powerturn swing door drive.
GEZE hold-open system FA GC 150 Wiring diagram Electromechanical swing door drive Powerturn F-IS/TS* Follow wiring diagram for the Powerturn swing door drive. Door closer Hold-open magnet Reed switch Reed switch closed if passive leaf is closed Latching Reset action cam Fig.
Wiring diagram GEZE hold-open system FA GC 150 5.8.4 Hold-open system TS 5000 R Fig. 5.8.4.1 5.8.5 Hold-open system TS 5000 R-ISM /G/S/0 TS 5000 R-ISM/G - no hold-open device in the passive leaf TS 5000 R-ISM/S - no hold-open device in the active leaf...
GEZE hold-open system FA GC 150 Wiring diagram 5.8.6 Hold-open system TS 5000 R-ISM-EFS / TS 5000 R-ISM/0 with Free swing door closer à No hold-open mechanism for the passive leaf à Connector box with plug-in cable transition, ID 052105...
Wiring diagram GEZE hold-open system FA GC 150 5.8.9 Hold-open system Slimdrive EMD F/R Follow wiring diagram for the Slimdrive EMD swing door drive. 24 V Reset - Latching action cam Fig. 5.8.9.1...
GEZE hold-open system FA GC 150 Wiring diagram 5.8. 1 0 Hold-open system Slimdrive EMD F/R-IS* Follow wiring diagram for the Slimdrive EMD swing door drive. 24 V Reset Latching action cam Fig. 5.8.10.1...
Wiring diagram GEZE hold-open system FA GC 150 5.8. 1 1 Hold-open system Powerturn F/R* Follow wiring diagram for the Powerturn swing door drive. 24 V Powerturn F DCU8 DCU801 DCU802 DCU800 Latching action Reset Fig. 5.8.11.1...
GEZE hold-open system FA GC 150 Wiring diagram 5.8. 1 2 Hold-open system Powerturn F/R-IS* Follow wiring diagram for the Powerturn swing door drive. 24 V Powerturn F GF Powerturn F SF DCU8 DCU8 DCU801 DCU801 DCU802 DCU800 DCU802 DCU800...
Wiring diagram GEZE hold-open system FA GC 150 5.8. 1 3 Hold-open system Powerturn F/R-IS/TS* Follow wiring diagram for the Powerturn swing door drive. 24 V Door closer Powerturn F GF DCU8 GND 24 V 55 56 63 mA Hold-open magnet...
GEZE hold-open system FA GC 150 Commissioning Commissioning Switch on the mains voltage. The state display of the lintel-mounted smoke switch lights up green. Remove the dust protection film or dust protection cap from the housing of the housing so that the smoke openings are clear.
The owner-operator must arrange this official approval test. The acceptance test may only be carried out by GEZE specialists, specialists authorised by GEZE (with GEZE com- petence training ) or specialists from an official test centre named by DIBt in the approval procedure.
An empty battery is indicated as a warning at the status LED of the wireless module GC 171 (see Chapter 4.5.1) Scope, result and time of the functional test must be documented in the GEZE test log for hold-open systems and made available to the owner-operator.
Need help?
Do you have a question about the FA GC 150 and is the answer not in the manual?
Questions and answers