Download Print this page

Table Of Contents - Xerox N24 Technical Instructions

Hide thumbs Also See for N24:

Advertisement

2
Photo 9
Photo 11
Photo 13
Photo 6
Photo 8
Photo 10
Photo 12
Photo 14
Xerox N24/32/40 Technical Instructions
Using a Philips screwdriver remove the
two screws holding the drum axle hub
on the contact side of the waste hopper.
(See Photo 5).
Remove the drum axle hub. (See Photo 6)
Rotate the waste hopper 180°. Remove
the two screws holding the drum axle
Remove the hub. (See Photos 8)
Step 6
Lift out the drum. (See Photos 9)
Step 7
Remove the PCR from the cradles.
(See Photos 10)
NOTE: Clean the PCR using a mild soap
and water.
Step 8
Carefully lift the waste hopper so it is up
on its end and the handle of the cartridge
is facing you. (See Photo 11)
NOTE: Do not flip the waste hopper so
the wiper blade is down, toner will spill
out of the hopper. Remove the screw
located just below the handle.
(See Photo 12)
Step 9
Take the waste hopper to the dump
station. Release the two clips located
on each end of the waste hopper cover.
(See Photo 13) Lift off the waste hopper
cover. (See Photo 14)