Download Print this page

Advertisement

Quick Links

B
• Operator's Manual
Copyright 2003 SciCan. All rights reserved.
Rev 1.0
www.scican.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the QUANTIM B and is the answer not in the manual?

Questions and answers

Summary of Contents for SciCan QUANTIM B

  • Page 1 • Operator’s Manual Copyright 2003 SciCan. All rights reserved. Rev 1.0 www.scican.com...
  • Page 2 Additional Information Specifications Contact Quote your model details, serial number and date of purchase when contacting your supplier All rights reserved. QUANTIM is a trademark of SciCan,Division of Lux and Zwingenberger Ltd. For all service and repair inquiries: In Canada/United States:...
  • Page 3 Quantim B S S 1 1 S S 5 5 S S 1 1 S S 5 5 L L 1 1 S S 2 2 L L 2 2 S S 3 3 L L 3 3 S S 4 4...
  • Page 4 Quantim B Introduction Thank you for choosing the SciCan QUANTIM B autoclave. Whilst unpacking check the unit for transit damage. If damage is found, please report this to the shipping agent immediately, in All ‘Type B’ vacuum cycles on this autoclave use the triple pulse writing, and then notify your dealer.
  • Page 5 Quantim B Introduction Please take time to read these instructions before using the autoclave. It is essential that the operator is correctly trained and a ‘Responsible Person’ has been assigned for the management of the autoclave. By following these simple step-by-step instructions you can ensure your instruments are correctly sterilized every time.
  • Page 6 Quantim B Operation (continued) Additional Operations 9. Cycle options i) Steam Penetration Test After each cycle the unit returns to the default cycle ‘C1i’- The ‘steam penetration test’ should be performed on a daily basis to 134˚C/4min Type ‘B’ Vacuum cycle for linen loads, wrapped, pouched, solid or hollow confirm that the unit is operating correctly.
  • Page 7: Essential Information

    Quantim B Essential Information To ensure the autoclave continues to operate correctly, it is important to follow the following points and to carry out the necessary care and maintenance procedures as specified. Do ensure that..Routine Care and Maintenance ... you read and follow these operating instructions.
  • Page 8: Troubleshooting

    Quantim B Troubleshooting Should a fault occur a visual and audible indication will be given. The nature of the fault can be determined by reference to the fault guide below. The recovery sequence allows access to any instruments within the autoclave and is the first step when rectifying a fault mode.
  • Page 9: Additional Information

    Manual Handling: Due to the weight of the unit two people are required when SciCan will not be so liable in the event that the purchaser has failed unpacking or moving the product. to adhere to the instructions contained herein or if the autoclave has...
  • Page 10: Specifications

    Quantim B Specifications Fuses: Fuses are located under the access panel on Chamber Capacities 16 litre 22 Litre the rear of the product. Overall product width 480mm 480mm WARNING! Disconnect the autoclave from the mains power supply Overall product height...
  • Page 11 Quantim B Notes...