Pveo Connection; Pve Standard Connection Data / Pinout - Danfoss PVE Series 4 Technical Information

Proportional valve groupfor pvg 32/100/120 and pvhc
Hide thumbs Also See for PVE Series 4:
Table of Contents

Advertisement

Technical Information
Technical Data
42
PVE, Series 4 for PVG 32/100/120 and PVHC

PVEO connection

AMP version of PVEO–DI
PVEO-DI
LED
U
DC
DI-B
Pin no.
U
1
DI-A
DC
2
3
4
U
Grey connector
Black connector
Hirschmann/DIN version of PVEO / PVEO–R
PVEO/PVEO-R
3
U
DC
U
DC
157-502.11

PVE standard connection data / pinout

PVEA /PVEH / PVEM / PVES / PVEU connection (also with float B, 4–pin)
Connector
U
S
AMP
pin 1
Hirschmann/DIN
pin 2
Deutsch
pin 1
On PVEM the error pin is not used and not connected (pin 3 Hirschmann/DIN). Ground pins are internally
connected.
Control (U
) for standard mounted PVEA / PVEH / PVEM / PVES
S
Function
Neutral
Q: P → A
Q: P → B
Control (U
) for standard mounted PVEU
S
Function
Neutral
Q: P → A
Q: P → B
520L0553 • Rev GD • Jan 2014
AMP version of PVEO/PVEO–R
DC2
P301 104
Deutsch version of PVEO
U
DC
pin 2
pin 1
pin 4
Voltage relative
0,5 • U
DC
0,5 → 0,25 • U
DC
0,5 → 0,75 • U
DC
PVEU
5 V
5 V → 2,5 V
5 V → 7,5 V
Gnd
Error
pin 3
pin 4
gnd
pin 3
pin 3
pin 2
PWM
50%
50% → 25%
50% → 75%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents