Operating Conditions: Process; Medium Temperature Range; Medium Pressure Range (Nominal Pressure); Rupture Disk (Optional, Only Promass F) - Endress+Hauser Proline Promass 84F Technical Information

Coriolis mass flow measuring system
Hide thumbs Also See for Proline Promass 84F:
Table of Contents

Advertisement

Proline Promass 84F, 84M

Medium temperature range

Medium pressure range
(nominal pressure)
!
#
Rupture disk (optional, only
Promass F)
Endress+Hauser

Operating conditions: Process

Sensor
• Promass F: –50 to +200 °C
• Promass F (High temperature version): –50 to +350 °C
• Promass M: –50 to +150 °C
Seals
• Promass F:
No internal seals
• Promass M:
– Viton: –15 to 200 °C
– EPDM: –40 to +160 °C
– Silikon: –60 to +200 °C
– Kalrez: –20 to +275 °C
– FEP sheathed (not for gas applications): –60 to +200 °C
Flanges
Promass F:
According to DIN PN 16 to 100 / according to ASME B16.5 Cl 150, Cl 300, Cl 600 / JIS 10K, 20K, 40K, 63K
Promass M:
According to DIN PN 40 to 100 / according to ASME B16.5 Cl 150, Cl 300, Cl 600 / JIS 10K, 20K, 40K, 63K
Promass M (high pressure version)
Measuring tubes, connector, couplings: max. 350 bar
Note!
Material load diagrams for the process connections can be found on → Page 58 ff.
Pressure ranges of secondary containment
• Promass F
– DN 8 to 50: 40 bar
– DN 80: 25 bar
– DN 100 to 150: 16 bar
– DN 250: 10 bar
• Promass M
– 100 bar
Warning!
In case a danger of measuring tube failure exists due to process characteristics, e.g. with corrosive process
fluids, we recommend the use of sensors whose secondary containment is equipped with special pressure
monitoring connections or rupture disks (ordering option). With the help of these connections, fluid collected
in the secondary containment in the event of tube failure can be bled off. This is especially important in high
pressure gas applications. These connections can also be used for gas circulation and/or detection.
Dimensions → Page 53
Further informationen → Page 54.