I/O Module Guide
For the HMC3000 Series
Your Industrial Control Solutions Source
Maple Systems, Inc. | 808 134
_____________________
www.maplesystems.com
th
St. SW, Suite 120, Everett, WA 98204 | 425.745.3229
For use with the following:
• HMC3000 Series
• Digital and Analog
I/O Modules

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HMC3-M0808P0401T and is the answer not in the manual?

Questions and answers

Summary of Contents for Maple Systems HMC3-M0808P0401T

  • Page 1 For the HMC3000 Series Your Industrial Control Solutions Source _____________________ www.maplesystems.com For use with the following: • HMC3000 Series • Digital and Analog I/O Modules Maple Systems, Inc. | 808 134 St. SW, Suite 120, Everett, WA 98204 | 425.745.3229...
  • Page 2: Copyright Notice

    COPYRIGHT NOTICE This manual is a publication of Maple Systems, Inc., and is provided for use by its customers only. The contents of the manual are copyrighted by Maple Systems, Inc.; reproduction in whole or in part, for use other than in support of Maple Systems equipment is prohibited without the specific written permission of Maple Systems.
  • Page 3: Table Of Contents

    Installing I/O Modules ............................6 Configuring the I/O Modules ..........................6 Common Terms and Definitions......................... 10 Configuring High-speed Counters ........................12 Configuring Pulse Width Modulation (PWM) Outputs ..................14 HMC3-M0808P0401T ........................... 19 Specifications ..............................19 Configuration ..............................21 Wiring: ................................23 HMC3-M0808Y0401T ........................... 27 Specifications ..............................
  • Page 4 Introduction Specifications ..............................57 Configuration ..............................59 Wiring: ................................61 HMC3-M1614Y............................. 64 Specifications ..............................64 Configuration ..............................65 Wiring: ................................66 HMC3-M1616P ............................68 Specifications ..............................68 Configuration ..............................69 Wiring: ................................70 HMC3000 Series I/O Module Guide...
  • Page 5: Introduction

    Description 8 Digital Inputs (2 high-speed pairs, up to 200kHz) 8 Digital Outputs (2 PWM, up to 200kHz) HMC3-M0808P0401T 4 Analog Inputs (Voltage: 0-5V, 0-10V Current: 0-20mA, 4-20mA, Thermocouple, RTD) 1 Analog Output (Voltage: 0-5V, 0-10V Current: 0-20mA, 4-20mA) 8 Digital Inputs (2 high-speed pairs, up to 200kHz)
  • Page 6: I/O Expansion Module Overview

    I/O Expansion Module Overview I/O Expansion Module Overview Each I/O terminal is labeled for easy identification on the modules. ‘COM’ is the common ground terminal. A terminal with an ‘X’ followed by a number is an input terminal and a terminal with a ‘Y’ followed by a number is an output terminal.
  • Page 7 I/O Expansion Module Overview 3. Double-click Slot 1 to display the IO Allocation dialog: 4. Select the particular I/O expansion module installed in Slot 1 of the HMC3000 from the drop-down Model selection menu. When the checkbox to ‘Add tags for XW, YW, and MW’ option is checked, MAPware-7000 automatically assigns tags to the Tag Database for the I/O module.
  • Page 8 I/O Expansion Module Overview the project, such as from a window or via a power-up task. The available options will depend on the module being configured. Select the channel and desired configuration, then click the Confirm button to save the configuration. 7.
  • Page 9 I/O Expansion Module Overview 8. For the Analog configuration of this module, the behavior is the same; choose the channel and the configuration, then click the Confirm button to complete the configuration. 9. Options for the Analog configuration of this specific module: HMC3000 Series I/O Module Guide...
  • Page 10: Common Terms And Definitions

    I/O Expansion Module Overview Common Terms and Definitions This section defines some common terms used to describe various types of inputs and outputs. The terms explained below are generic descriptions. Be sure to consult the datasheet for the specific requirements when installing and wiring a module.
  • Page 11 I/O Expansion Module Overview Digital Outputs (PNP or NPN type) The output terminals of a digital I/O module use an optically isolated PNP or NPN transistor to energize the connected load. PNP/NPN outputs are faster than relay outputs but can only work with low current DC loads (typically 500mA max per terminal).
  • Page 12: Configuring High-Speed Counters

    I/O Expansion Module Overview Configuring High-speed Counters Maple Systems’ HMC modules have built-in High-Speed counters that link directly to specific inputs and outputs. Specific registers and bits are predefined for setup and control of these counters. No logic is required to run the counters, other than logic that may be used for configuration and control.
  • Page 13 I/O Expansion Module Overview HSC Configuration Register Bit table Bits Function 15-12 Not used 11-10 00: Reset counter if SW Reset bit or physical I/Preset bit goes from 0 to 1 01: Reset counter if the SW reset bit goes from 0 to 1 11: reserved for future use Forced Output Configuration 0: Forced output ON for Preset 1...
  • Page 14: Configuring Pulse Width Modulation (Pwm) Outputs

    Configuring Pulse Width Modulation (PWM) Outputs Maple Systems’ HMC3000 I/O modules have built-in Pulse Width Modulation functionality. Specific registers and bits are predefined for setup and control of these functions. No logic is required to run the PWM, other than logic that may be used to configure and control them.
  • Page 15 I/O Expansion Module Overview Function Register Description Output, PWM Pulse Y0 (Channel 1) Y1 (Channel 2) Physical Output Configuration Register MWnn24 MWnn30 Value = 1 for this mode Frequency Setting Register MWnn25 MWnn31 Range = 1 to 200000 ON Duty Setting Register (Duty Cycle) MWnn27 MWnn33 Range = 0 to 100...
  • Page 16 I/O Expansion Module Overview CW/CCW When the frequency is positive, the output signal is generated on Channel 1, and Channel 2 is not used. When the frequency value is negative, the output signal is generated on Channel 2, and Channel 1 is not used. The frequency can be adjusted while running (place a 4 in the Config register instead of 3), and the Duty Cycle is fixed at 50%.
  • Page 17 I/O Expansion Module Overview Pulse/Direction The output signal is generated on Channel 1. If the frequency value is positive, Channel 2 is held low. If the frequency value is negative, Channel 2 is held high. The frequency can be adjusted while running (place an 8 in the configuration register), and the Duty Cycle is fixed at 50%.
  • Page 18 I/O Expansion Module Overview Fixed Pulse Mode The output signal is generated on Channel 1. The frequency ramps up from the minimum frequency to the maximum frequency in the interval specified by acceleration time. The output signal is generated until the specified number of pulses has been sent.
  • Page 19: Hmc3-M0808P0401T

    HMC3-M0808P0401T HMC3-M0808P0401T 8 Digital Inputs (2 high-speed pairs up to 200kHz) 8 Digital Outputs (2 PWM up to 200kHz) 4 Universal Analog Inputs • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA • Thermocouple • 1 Analog Output • Voltage: 0-5V, 0-10V •...
  • Page 20 HMC3-M0808P0401T 4 Inputs, each configurable as: • 0 to 50mV, 0 to 100 mV; 0 to 10V, 0 to 5V; • 0 to 20mA, 4-20mA; • PT100 RTD, alpha1 [0.00385 Ω/Ω°C] (-200 to 850 C); Analog Inputs • PT100 RTD, alpha2 [0.003926 Ω/Ω°C] (-100 to 457 C);...
  • Page 21: Configuration

    HMC3-M0808P0401T Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05):...
  • Page 22 HMC3-M0808P0401T Reference the table below when configuring each HSC Configuration Register: Input Mode Output Mode Register Value Normal Input High Speed, Output ON when preset is reached Single Phase, Output ON when counter is enabled, Up/Down Counter OFF when preset is reached...
  • Page 23: Wiring

    HMC3-M0808P0401T Reference the table below when configuring the Analog Output Configuration Register (MWnn68): Output Signal Type Register Value Voltage, 0 to 10V Voltage, 0 to 5V Current, 4 to 20mA Current, 0 to 20mA Analog expansion modules have an analog output resolution of 12 bits with values ranging from 0-4095.
  • Page 24 HMC3-M0808P0401T Analog Input (Voltage) Analog Input (Current) Analog Input (mV / Thermocouple) Analog Input (RTD) HMC3000 Series I/O Module Guide...
  • Page 25 HMC3-M0808P0401T Analog Output (Voltage) Analog Output (Current) HSC Single Phase Up Counter HSC Single Phase Down Counter HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 26 HMC3-M0808P0401T HMC3000 Series I/O Module Guide...
  • Page 27: Hmc3-M0808Y0401T

    HMC3-M0808Y0401T HMC3-M0808Y0401T 8 Digital Inputs (2 high-speed pairs up to 200kHz) 8 Digital Outputs (6 Relay, 2 PNP w/ PWM up to 200kHz) 4 Universal Analog Inputs • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA • Thermocouple • 1 Analog Output •...
  • Page 28 HMC3-M0808Y0401T 4 Inputs, each configurable as: • 0 to 50mV, 0 to 100 mV; 0 to 10V, 0 to 5V; • 0 to 20mA, 4-20mA; • PT100 RTD, alpha1 [0.00385 Ω/Ω°C] (-200 to 850 C); Analog Inputs • PT100 RTD, alpha2 [0.003926 Ω/Ω°C] (-100 to 457 C); •...
  • Page 29: Configuration

    HMC3-M0808Y0401T Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 30 HMC3-M0808Y0401T Reference the table below when configuring each HSC Configuration Register: Input Mode Output Mode Register Value Normal Input High Speed, Output ON when preset is reached Single Phase, Output ON when counter is enabled, Up/Down Counter OFF when preset is reached Quadrature 4X Output ON when preset is reached Output ON when counter is enabled,...
  • Page 31: Wiring

    HMC3-M0808Y0401T Reference the table below when configuring the Analog Output Configuration Register (MWnn68): Output Signal Type Register Value Voltage, 0 to 10V Voltage, 0 to 5V Current, 4 to 20mA Current, 0 to 20mA Analog expansion modules have an analog output resolution of 12 bits with values ranging from 0-4095. Expansion Module Output Values Reg Value...
  • Page 32 HMC3-M0808Y0401T Analog Input (Voltage) Analog Input (Current) Analog Input (mV / Thermocouple) Analog Input (RTD) HMC3000 Series I/O Module Guide...
  • Page 33 HMC3-M0808Y0401T Analog Output (Voltage) Analog Output (Current) HSC Single Phase Up Counter HSC Single Phase Down Counter HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 34 HMC3-M0808Y0401T HMC3000 Series I/O Module Guide...
  • Page 35: Hmc3-M1212P0200

    HMC3-M1212P0200 HMC3-M1212P0200 12 Digital Inputs (2 high-speed pairs up to 200kHz) 12 Digital Outputs (2 PWM up to 1kHz) 4 Universal Analog Inputs • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA This module is an input/output module for the HMC3000 Series models. It has twelve digital inputs, two of which are high-speed pairs and 12 sourcing digital outputs.
  • Page 36 HMC3-M1212P0200 Digital Outputs 12 sourcing outputs (PNP-type), 2 PWM Maximum PWM Output Frequency 1KHz Minimum ON Output Voltage 22 VDC Maximum ON Output Voltage 30 VDC Minimum OFF Output Voltage 0.2 VDC Maximum OFF Output Voltage 1 VDC Rated Load 250mA @ 24VDC 96...
  • Page 37: Configuration

    HMC3-M1212P0200 Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 38 HMC3-M1212P0200 Reference the table below when configuring the PWM Configuration Registers: Output Mode Register Value Normal PWM (fixed frequency) Normal PWM (variable frequency) CW/CCW (fixed frequency) CW/CCW (variable frequency) Pulse/Direction (fixed frequency) Pulse/Direction (variable frequency) Trapezoidal (Fixed Pulse Mode) Reference the table below when configuring each Analog Input Configuration Register (MWnn60-MWnn61): Input Signal Type Register Value Voltage, 0 to 10V...
  • Page 39: Wiring

    HMC3-M1212P0200 Wiring: Digital Inputs Digital Outputs Analog Input (Voltage) Analog Input (Current) HMC3000 Series I/O Module Guide...
  • Page 40 HMC3-M1212P0200 HSC Single Phase Up Counter HSC Single Phase Down Counter HMC3000 Series I/O Module Guide...
  • Page 41 HMC3-M1212P0200 HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 42: Hmc3-M1212Y0200

    HMC3-M1212Y0200 HMC3-M1212Y0200 12 Digital Inputs (2 high-speed pairs up to 200kHz) 12 Digital Outputs (10 Relay, 2 PNP w/ PWM up to 1kHz) 4 Universal Analog Inputs • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA This module is an input/output module for the HMC3000 Series models. It has eight digital inputs, two of which are high-speed pairs and 12 digital outputs.
  • Page 43 HMC3-M1212Y0200 Digital Outputs 12 outputs: 10 Relay, 2 Sourcing (PNP-type) / PWM Maximum PWM Output Frequency 1KHz Minimum ON Output Voltage 22 VDC Maximum ON Output Voltage 30 VDC Minimum OFF Output Voltage 0.2 VDC Maximum OFF Output Voltage 1 VDC 250mA @ 24VDC Rated Load 2A @230VAC...
  • Page 44: Configuration

    HMC3-M1212Y0200 Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 45 HMC3-M1212Y0200 Reference the table below when configuring the PWM Configuration Registers: Output Mode Register Value Normal PWM (fixed frequency) Normal PWM (variable frequency) CW/CCW (fixed frequency) CW/CCW (variable frequency) Pulse/Direction (fixed frequency) Pulse/Direction (variable frequency) Trapezoidal (Fixed Pulse Mode) Reference the table below when configuring each Analog Input Configuration Register (MWnn60-MWnn61): Input Signal Type Register Value Voltage, 0 to 10V...
  • Page 46: Wiring

    HMC3-M1212Y0200 Wiring: Digital Inputs Digital Outputs Analog Input (Voltage) Analog Input (Current) HMC3000 Series I/O Module Guide...
  • Page 47 HMC3-M1212Y0200 HSC Single Phase Up Counter HSC Single Phase Down Counter HMC3000 Series I/O Module Guide...
  • Page 48 HMC3-M1212Y0200 HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 49: Hmc3-M1210P0201

    HMC3-M1210P0201 HMC3-M1210P0201 12 Digital Inputs (2 high-speed pairs up to 200kHz) 10 Digital Outputs (2 PWM up to 1kHz) 4 Universal Analog Inputs • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA 1 Analog Output • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA This module is an input/output module for the HMC3000 Series models.
  • Page 50 HMC3-M1210P0201 Digital Outputs 10 sourcing outputs (PNP-type), 2 PWM Maximum PWM Output Frequency 1KHz Minimum ON Output Voltage 22 VDC Maximum ON Output Voltage 30 VDC Minimum OFF Output Voltage 0.2 VDC Maximum OFF Output Voltage 1 VDC Rated Load 250mA @ 24VDC 96...
  • Page 51: Configuration

    HMC3-M1210P0201 Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 52 HMC3-M1210P0201 Reference the table below when configuring the PWM Configuration Registers: Output Mode Register Value Normal PWM (fixed frequency) Normal PWM (variable frequency) CW/CCW (fixed frequency) CW/CCW (variable frequency) Pulse/Direction (fixed frequency) Pulse/Direction (variable frequency) Trapezoidal (Fixed Pulse Mode) Reference the tables below when configuring each Analog Input and Output Configuration Register: Input Signal Type Register Value Output Signal Type...
  • Page 53: Wiring

    HMC3-M1210P0201 Wiring: Digital Inputs Digital Outputs Analog Input (Voltage) Analog Input (Current) HMC3000 Series I/O Module Guide...
  • Page 54 HMC3-M1210P0201 Analog Output (Voltage) Analog Output (Current) HSC Single Phase Up Counter HMC3000 Series I/O Module Guide...
  • Page 55 HMC3-M1210P0201 HSC Single Phase Down Counter HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 56 HMC3-M1210P0201 HMC3000 Series I/O Module Guide...
  • Page 57: Hmc3-M1210Y0201

    HMC3-M1210Y0201 HMC3-M1210Y0201 12 Digital Inputs (2 high-speed pairs up to 200kHz) 10 Digital Outputs (8 Relay, 2 PNP w/ PWM up to 1kHz) 4 Universal Analog Inputs • Voltage: 0-5V, 0-10V • Current: 0-20mA, 4-20mA 1 Analog Output • Voltage: 0-5V, 0-10V •...
  • Page 58 HMC3-M1210Y0201 Digital Outputs 10 outputs: 8 Relay, 2 Sourcing (PNP-type) / PWM Maximum PWM Output Frequency 1KHz Minimum ON Output Voltage 22 VDC Maximum ON Output Voltage 30 VDC Minimum OFF Output Voltage 0.2 VDC Maximum OFF Output Voltage 1 VDC 250mA @ 24VDC Rated Load 2A @230VAC...
  • Page 59: Configuration

    HMC3-M1210Y0201 Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 60 HMC3-M1210Y0201 Reference the table below when configuring the PWM Configuration Registers: Output Mode Register Value Normal PWM (fixed frequency) Normal PWM (variable frequency) CW/CCW (fixed frequency) CW/CCW (variable frequency) Pulse/Direction (fixed frequency) Pulse/Direction (variable frequency) Trapezoidal (Fixed Pulse Mode) Reference the tables below when configuring each Analog Input and Output Configuration Register: Input Signal Type Register Value Output Signal Type...
  • Page 61: Wiring

    HMC3-M1210Y0201 Wiring: Digital Inputs Digital Outputs Analog Input (Voltage) Analog Input (Current) HMC3000 Series I/O Module Guide...
  • Page 62 HMC3-M1210Y0201 Analog Output (Voltage) Analog Output (Current) HSC Single Phase Up Counter HMC3000 Series I/O Module Guide...
  • Page 63 HMC3-M1210Y0201 HSC Single Phase Down Counter HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 64: Hmc3-M1614Y

    HMC3-M1614Y HMC3-M1614Y 16 Digital Inputs (2 high-speed pairs up to 200kHz) 14 Digital Outputs (12 Relay, 2 PNP w/ PWM up to 1kHz) This module is a digital input/output module for the HMC3000 Series models. It has 16 digital inputs, 2 of which are high-speed pairs. The module also features 14 digital outputs, 2 sourcing (PNP) outputs capable of PWM operation and 12 relay type outputs.
  • Page 65: Configuration

    HMC3-M1614Y Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 66: Wiring

    HMC3-M1614Y Wiring: Digital Inputs Digital Outputs HSC Single Phase Up Counter HMC3000 Series I/O Module Guide...
  • Page 67 HMC3-M1614Y HSC Single Phase Down Counter HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 68: Hmc3-M1616P

    HMC3-M1616P HMC3-M1616P 16 Digital Inputs (2 high-speed pairs up to 200kHz) 16 Digital Outputs (2 PWM up to 1kHz) This module is a digital input/output module for the HMC3000 Series models. It has 16 digital inputs, 2 of which are high-speed pairs. The module also features 16 digital sourcing (PNP) outputs, 2 of which can be used for PWM operation.
  • Page 69: Configuration

    HMC3-M1616P Configuration Use MAPware-7000 to assign input (X and XW), output (Y and YW) and configuration (M and MW) memory addresses to the module. These addresses are created according to the slot location of the module, where nn refers to the slot number (ex. 01…05): Function Register Access...
  • Page 70: Wiring

    HMC3-M1616P Wiring: Digital Inputs Digital Outputs HSC Single Phase Up Counter HMC3000 Series I/O Module Guide...
  • Page 71 HMC3-M1616P HSC Single Phase Down Counter HSC Quadrature HMC3000 Series I/O Module Guide...
  • Page 72 HMC3-M1616P HMC3000 Series I/O Module Guide...
  • Page 73 Your Industrial Control Solutions Source _____________________ www.maplesystems.com 1010-1056 Rev. 04 Maple Systems, Inc. | 808 134 St. SW, Suite 120, Everett, WA 98204 | 425.745.3229...