Configuration
Byte offset in
variables mem-
ory
45-46
Remote TSAP
S7 connection 2 section (If not all bytes are used in this section, they should be filled in with
16#00)
47
Flag byte
See S7 connection 0 section.
48-49
IP address of partner
See S7 connection 0 section.
52-53
Local TSAP
54-55
Remote TSAP
S7 connection 3 section (If not all bytes are used in this section, they should be filled in with
16#00)
56
Flag byte
See S7 connection 0 section.
57-60
IP address of partner
See S7 connection 0 section.
61-62
Local TSAP
63-64
Remote TSAP
S7 connection 4 section (If not all bytes are used in this section, they should be filled in with
16#00)
65
Flag byte
See S7 connection 0 section.
66-69
IP address of partner
See S7 connection 0 section.
70-71
Local TSAP
72-73
Remote TSAP
S7 connection 5 section (If not all bytes are used in this section, they should be filled in with
16#00)
74
Flag byte
See S7 connection 0 section.
75-78
IP address of partner
See S7 connection 0 section.
79-80
Local TSAP
81-82
Remote TSAP
40
Description
Data format
2 bytes hex
See S7 connection 0
section.
1 byte hex
See S7 connection 0
section.
4 bytes hex
See S7 connection 0
section.
2 bytes hex
16#1200
2 bytes hex
See S7 connection 0
section.
1 byte hex
See S7 connection 0
section.
4 bytes hex
See S7 connection 0
section.
2 bytes hex
16#1300
2 bytes hex
See S7 connection 0
section.
1 byte hex
See S7 connection 0
section.
4 bytes hex
See S7 connection 0
section.
2 bytes hex
16#1400
2 bytes hex
See S7 connection 0
section.
1 byte hex
See S7 connection 0
section.
4 bytes hex
See S7 connection 0
section.
2 bytes hex
16#1500
2 bytes hex
See S7 connection 0
section.
J31069-D0428-U001-A1-7618
09/02
Example
CP 243-1