Introduction; About This Manual - CareFusion Alaris CC Guardrails 80033UND1-G Directions For Use Manual

Syringe pump
Table of Contents

Advertisement

The Alaris® CC Guardrails® Syringe Pump (herein after referred to as "pump") is a fully featured high end variable pressure syringe pump
suitable for critical care applications.
The Alaris® CC Guardrails® Syringe Pump functions with a wide range of standard, single-use, disposable Luer lock syringes together with
extension sets. It accepts syringe sizes from 5ml to 50ml. A full list of compatible syringes can be found in the Compatible Syringes section.
A list of recommended extension sets can be found in the Compatible Extension Sets section.
The Guardrails® Safety Software for the Alaris® CC Guardrails® Syringe Pump brings a new level of medication error prevention to the point
of patient care. The Guardrails® Safety Software allows the hospital to develop a best-practice Data Set of IV medication dosing guidelines for
patient-specific care areas, referred to as profiles. Each profile contains a specific library of drugs, as well as pump configurations appropriate
for the care area. A profile also contains either Guardrails® Hard Limits that cannot be overridden during infusion programming, or Guardrails®
Soft Alerts that can be overridden, based on clinical requirements.
The hospital defined Data Set is developed and approved through pharmacy and clinical input, and then configured into the Alaris® CC
Guardrails® Syringe Pump by qualified technical personnel.
The Alaris® CC Guardrails® Syringe Pump, with a Data Set loaded, provides automatic alerts when a dosing limit, bolus limit, concentration
limit, or weight limit has been exceeded. These safety alerts are provided without the need for the pump to be connected to a PC or network.
Intended Purpose
The Alaris® CC Guardrails® Syringe Pump is intended for use by medical staff for purposes of controlling infusion rate and
volume.
Conditions of Use
The Alaris® CC Guardrails® Syringe Pump should only be operated by a clinician competent in use of automated syringe
pumps and post-placement management of intravenous catheters.
CareFusion cannot guarantee the continued system accuracy with other manufacturer's syringes as identified in the
w
'Compatible Syringes' table. Manufacturers may change syringe specification significant to system accuracy without
prior notification.
Indications
The Alaris® CC Guardrails® Syringe Pump is indicated for infusion of therapeutics including:
• analgesics
• antimicrobials
• blood products
• chemotherapy
• nutrition
• subcutaneous
• epidural
Contraindications
The Alaris® CC Guardrails® Syringe Pumps is contraindicated for:
• enteral therapies
The user must be thoroughly familiar with the Alaris® CC Guardrails® Syringe Pump described in this manual prior to use.
All illustrations used in this manual show typical settings and values which may be used in setting up the functions of the pump. These
settings and values are for illustrative use only.
intermediate infusion rate refers to a nominal rate of 5.0ml/h. The complete range of infusion rates, settings and values are shown in the
Specifications section.
It is important to ensure that you only refer to the most recent version of the Directions for Use and Technical Service
w
Manual for your CareFusion products. These documents are referenced on www.carefusion.com. Copies can be
obtained by contacting your local CareFusion representative.

Introduction

About This Manual

Where stated, a minimum infusion rate refers to a nominal rate of 1.0ml/h, and an
1000DF00333 Issue 6
2/38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents