GE AF-60 LP Programming Manual page 25

Micro drive
Hide thumbs Also See for AF-60 LP:
Table of Contents

Advertisement

2-20 Release Brake Current
Range:
*
0.00 A
[0.00 - 100 A]
2-22 Activating Mechanical Brake
Range:
4
*
0 Hz
[0 - 400 Hz]
24
Function:
Select motor current at which mechanical brake releases.
If start delay time has passed, and motor current is below Release brake current, frequency converter
trips.
Function:
If the motor is stopped using ramp, the mechanical brake is activated when motor speed is less than Active Brake
Speed.
Motor is ramped down to stop in the following situations:
A start command is removed (stand by)
A stop command is activated
Quick-stop is activated (Q-stop ramp is used)
Select motor speed at which mechanical brake activates when ramping down.
Mechanical brake automatically activates if frequency converter trips or reports an alarm.
AF-60 LP™ Micro Drive Programming Guide