Automatic temperature monitoring for coordinate measuring machines

Advertisement

Operating manual

TEMPAR console
Automatic temperature monitoring for
coordinate measuring machines
Article no.: 626140-9149-831

Advertisement

Table of Contents
loading

Summary of Contents for Zeiss TEMPAR console

  • Page 1: Operating Manual

    Operating manual TEMPAR console Automatic temperature monitoring for coordinate measuring machines Article no.: 626140-9149-831...
  • Page 3 The replication of trade names and such in this document does not justify the assumption that such names should, in the sense of trademark and brand protection legislation, be regarded as unused and therefore usable by anyone. Layout, illustration, photos and texts: Carl Zeiss 3D Automation GmbH Printed in Germany 03/2019...
  • Page 4: Table Of Contents

    3.3 Operation as "Viewer" user ......51 Operating manual TEMPAR console V9.0...
  • Page 5 5 Technical data ........54 5.1 Scope of supply and expansions ......56 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 6 Abbreviations The abbreviated terms in this document have the following meanings: Coordinate measuring machine DAkkS German Accreditation Body German Calibration Service DHCP Dynamic Host Configuration Protocol 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 7: Product Description

    Alongside the temperature, other physical quantities can also be measured. The sensors can be attached to the ceiling or to the wall. Alternatively, they can also be erected with the mobile measuring stand. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 8 DAkkS-calibrated sensor serving as a reference. The optional sensors for air pressure, humidity and airflow can also be calibrated at the factory or by DAkkS. All sensors are shipped with a calibration certificate. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 9 Product description The TEMPAR console enables measured values from the sensors to be recorded, displayed and saved depending on the configuration level. It displays the history of the measured valves and indicates when they exceed or fall below the limit values.
  • Page 10: Legal And Safety

    Warranty Our General Terms and Conditions of Sale and Delivery always apply. These are available online at www.probes.zeiss.com. No warranty or liability claims for personal injury or material damage can be accepted if they relate to one or more of the causes given below: –...
  • Page 11 FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 12: Intended Use

    – No other chargers should be used other than those provided with the devices specifically for their charging. – Store sensor units in clean and dry conditions. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 13: Misuse

    – Operating or maintenance to the system by unauthorised personnel. – Use in rooms not permitted for the TEMPAR system. – Changing or modifying the system without authorisation. – Failure to comply with valid laws, regulations, safety instructions or the manual. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 14: Operation

    There may not be any per-hour and per-day measured values present directly after switching the system on. They must first be collected for the corresponding time frame, before valid gradients can be displayed. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 15 All users can set the language of the console using the country flags on the top right: Fig. 5: Selecting the language The IP address and the console ID are shown under the login window (on left in the corner). 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 16: Operation As "Standard" User Group

    Information about the measuring room is displayed in the "Dashboard" tab by means of widgets. The dashboard user interface can be configured according to the user's requirements using widgets. The dashboard can be individually configured for each user. Widget selection menu Fig. 8: 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 17 – Temperature 1, 2, 3, ... – Rate of temperature change per hour – Rate of temperature change per day – Time – Machine – Battery level of sensors that are wirelessly connected Fig. 9: Widget selection 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 18 Fig. 10: Widget: Display of the current value of “Temperature 5” Fig. 11: Widget: Display of the temperature history as a chart To remove a widget from the window, select it and drag it to any vacant area. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 19: Machines" Menu

    – The time until the next calibration in – The number of unacknowledged errors – The number of unacknowledged warnings By clicking on the errors or warnings buttons, the "Event Log” menu is opened with the listed warnings and errors. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 20: Measuring Room" Menu

    (see also "Configuration/Measuring Room/Classification"). Values in black belong to the displayed measuring room quality class. Values in green comply with a better measuring room quality class. 3.2.4 "Sensors" menu Fig. 15: "Sensors" menu 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 21 Fig. 16: Additional information about the sensors If changes have been made to the sensors or settings in the system, it can take a while for these to be fully incorporated in the calculations. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 22: History" Menu

    To the right, a predefined or freely definable period is selected. The two settings are used to generate a chart. Provided a selection has already been made, the values of the last selection are immediately displayed. Fig. 18: History - chart 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 23 (zoom function). The area can be expanded or reduced using the bar below the chart. With the right button "Display all” you go back to the entire chart view according to the time interval specified above. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 24: System" Menu

    For the factory-calibrated sensors, the value represents the deviation from the DAkkS-calibrated sensors. The "Test Laboratory" column shows the identification code of the test laboratory. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 25: Csv Export" Menu

    When exporting from e.g. a PC, the storage location can be freely selected. Under Configuration > System > General > CSV Export, the decimal separating character ("." or ",”) can be set as the decimal separator for the file to be exported. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 26: Event Log" Menu

    – Information items are system messages – Warnings are of informative nature, e.g. exceeding of limit values – Errors indicate malfunctions A targeted search of messages can be performed using the filter and search function. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 27: Configuration > System > General" Menu

    Via the "Configuration" menu at the top right, the "System" sub-menu, which is subdivided into several tabs, can be accessed. You can return to the standard view by clicking on the ZEISS logo. The "General” tab displays general information and allows settings to be made.
  • Page 28: Configuration > System > Network" Menu

    After changing the settings, activate the button “Apply network settings to the operating system”. If the network connection is to be made via a proxy server, this can be configured by selecting the option “Use HTTP(S) Proxy Server”. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 29: Configuration > System > User" Menu

    – May change users: requires standard user group and allows the user themselves to create or modify other users. If this option is not activated, then only the individual user can be edited. Fig. 26: Creating a user 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 30: Configuration > System > Database" Menu

    "Database" graphically shows the amount of space the system still has available. To purge measuring data, select the desired time period and click on "Purge”. 3.2.13 "Configuration > System > Maintenance" menu Fig. 28: "Maintenance" menu The "Maintenance” tab contains the following functions: 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 31: Configuration > System > Maintenance" Menu

    The following data is required for login. The data can be taken from "Configuration > System > General" menu. (See chapter "3.2.9 "Configuration > System > General" menu") For example: Console Serial Number: TMPR-C-12345678 Console ID: 00:aa:11:bb:22:cc Click "Download" to download the current TEMPAR version. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 32 To perform an online update the console must have internet access. Query for new updates via the "Check for Update” button. Download the new update via the "Start download to console” button. The update process must be started after the download finishes. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 33: Configuration > System > Backup" Menu

    Alternatively a backup can be stored to a shared network resource (Network Share) which can be accessed from the TEMPAR console. To do so first create a folder on a Windows system and enable for network (shared) access.
  • Page 34: Configuration > System > External Db" Menu

    There are two possibilities for linking to PiWeb. The first possibility is a data exchange by transferring the file to a network share and an import into PiWeb using PiWeb auto importer. The second possibility is direct communication with the PiWeb server via a REST interface. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 35 The folder name entered here must match that in the Computer Management of the PiWeb PC. However, you can create subfolders in the enabled folder, the path of which, relating to the enabled folder, is entered here. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 36 PiWeb is created in the specified folder. Fig. 35: Folder structure (example) – Then the “TEMPAR” folder and its subfolder, which is automatically created by TEMPAR, must still be manually created in the PiWeb Planner as components and subcomponents. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 37 PiWeb server version must be displayed in TEMPAR (if necessary, the TEMPAR page must be reloaded, e.g. by switching between tabs). – After a brief period, data are created in the PiWeb database. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 38 – The files with the measured values are created in the enabled folder according to the "Interval measuring data (ms)” (See chapter "3.2 Operation as “Standard” user group") in the enabled folder. Naming takes place according to the following template: “Q-DAS_<Seriennummer Konsole/Messzone>_YYYYMMDD-hhmmss.DFQ”. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 39: Configuration > System > Connections" Menu

    TEMPAR cockpit operating instructions). There is normally no need to make any settings in the "Management Interface" area unless you are instructed to do so by a ZEISS employee. Clicking on “Test connection” causes a test to be performed on whether the Management Interface can be reached with the current settings.
  • Page 40: Configuration > Measuring Room > Machines" Menu

    In the "Machines" area, up to ten test and measuring machines can be selected that are to be monitored from the console. The specification values can be set for each machine. In addition to the Carl ZEISS machines listed, ten freely configurable entries are available (CMM 1 to CMM 10).
  • Page 41 Images can be uploaded for each machine in the "Logo” column. These images are displayed as the machine logo in the main tabs. If only one image is uploaded for the machine, it is shown framed in orange in a warning. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 42: Configuration > Measuring Room > Sensors" Menu

    Operation 3.2.18 "Configuration > Measuring Room > Sensors" menu Fig. 38: "Sensors" menu 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 43 – Display: Sensor reachable or not reachable. Sensors that cannot be reached can be deleted by clicking the top right minus sign. – Sensor serial number – Sensor network address 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 44 1500 seconds). If for example a time constant of 1500 seconds is set, a temperature change of 1 K would only cause a change to the measuring result of 1 K after 1500 seconds. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 45: Configuration > Measuring Room > Calibration" Menu

    Also the number of days before the calibration runs out at which point a warning and an alarm are issued can be specified here. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 46: Configuration > Measuring Room > Tolerance Values" Menu

    If these tolerance values are exceeded or undershot, the font colour of the displayed values changes from black to orange and a warning is generated and displayed in the EventLog. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 47: Configuration > Measuring Room > Profile" Menu

    Here, the Y-axis sections of the charts in the main "History" tab are set for chart, temperature, air humidity, air pressure and air flow. The Y-axis sections or all other charts are fixed or can be defined automatically by the system using "Automatic Scaling". 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 48: Configuration > Measuring Room > Classification" Menu

    While the special measuring room is active, a check is only performed as to whether the measuring room is within the specification for the special measuring room or not. Measuring room classes 1 to 4 are not considered. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 49: Configuration > Measuring Room > Event Log" Menu

    – Add event log reason General "Event Log" can be switched on and off here. Delete log entries Existing log entries can be deleted in this area. Select the period for this and click the "Delete" button. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 50 User defined reasons User defined reasons can be viewed, edited or deleted here. Add event log reason Your own reasons can be entered and added here. Afterwards, they can be found under "User-defined reasons". 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 51: Operation As "Viewer" User

    Alternatively the console can also be switched off by pressing the “On/Off button” (See chapter "3.1 Switching on"). Note: The console must be switched off and disconnected from the power source for installation or maintenance work. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 52: Maintenance

    All sensors can be replaced and consequently the measuring process can be recommenced within a very shot time period. Then the sensors with the lapsed calibration must be sent back to Carl Zeiss 3D Automation. Contact: Carl Zeiss 3D Automation GmbH...
  • Page 53: Disposal And Recycling

    When disposing of the system or its components, different elements must be disposed of separately in accordance with relevant national and regional waste disposal regulations. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 54: Technical Data

    The composition of walls and the ceiling must be sufficient for being able to fasten the TEMPAR system. Fastening materials like cable ducts, screws and plugs must be selected by the operator depending on the composition. 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 55 Technical data TEMPAR wireless Condition Value Measuring interval Dependent on the settings on the TEMPAR console, at least 30 seconds Service life With lighting of at least 300 Lux: > 10 years Battery type LiFePO (lithium iron phosphate) Number of loading cycles...
  • Page 56: Scope Of Supply And Expansions

    TEMPAR Logic Box 626140-9140-213 TEMPAR console 626140-9140-214 TEMPAR console cockpit 626140-9140-062 Signal device set for TEMPAR console v3 626140-9141-042 TEMPAR single temperature sensor, DAkkS calibrated 626140-9141-043 TEMPAR single temperature sensor, factory calibrated 626140-9141-052 TEMPAR precision single temperature sensor, DAkkS calibrated...
  • Page 57 Sensor bus cable M12 - 5.0 m 626140-9149-051 Sensor bus cable M12 - 5.0 m, plenum rated (CMP) 626140-9149-100 Sensor bus cable M12 - 10 m 626140-9149-101 Sensor bus cable M12 - 10 m, plenum rated (CMP) 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 58 Recalibration air pressure sensor, factory - alt 626140-8142-012 Recalibration humidity sensor, DAkkS 626140-8142-013 Recalibration humidity sensor, factory 626140-8143-012 Recalibration air pressure sensor, DAkkS 626140-8143-013 Recalibration air pressure sensor, factory 626140-8142-022 Recalibration air flow, DAkkS 626140-8142-023 Recalibration air flow, factory 626140-9149-911 Operating manual TEMPAR console V9.0...
  • Page 59 Calibration exchange service airflow sensor, factory Spare parts Item no. Designation 626140-9140-086 TEMPAR connection set for console 626140-9149-910 TEMPAR cockpit documentation 626140-9149-911 TEMPAR documentation 626140-9149-912 TEMPAR logic documentation 626140-9140-093 TEMPAR sensor bus terminal resistor 626140-9149-911 Operating manual TEMPAR console V9.0...