Specific functions of model 0995 Vetrano Dosata 2 Boiler PID
Ita
Filling Timeout
lia
no
If the boiler filling takes longer than 120 seconds, the machine generates an
alarm with an intermittent acoustic warning and flashing of the dosing keys. In
this alarm condition the boiler heating does not start.
D
eu
This condition may occur if the machine is switched on for the first time, with the
tsc
boiler completely empty.
h
Switch the machine off, then on again to restart the filling.
En
If the problem persists, make sure there are no water leakages or clogging in
gli
the hydraulic circuit.
sh
No water in tank
Fr
If the water in the tank drops below minimum level, the machine generates an
an
alarm with an intermittent acoustic warning and flashing of the dosing keys.
ça
To exit from alarm condition, it is sufficient to fill the tank.
is
When the machine is in alarm condition due to lack of water in the tank, the
boiler continues to heat and the water level can be topped-up. This is also
possible when the heating is interrupted due to lack of water in the boiler.
Dosing the coffee if there is no water in the tank
If during coffee delivery there is insufficient water in the tank, the machine only
generates an alarm after the delivery terminates.
LEDS on-off
On the models where these are fitted, the LEDs on the sides of the machine
can be switched on or off through switch (x), underneath the machine on the
right side.