Quick MILL MILANO 0980 Operating Instructions Manual page 24

Professional home coffee machines
Hide thumbs Also See for MILANO 0980:
Table of Contents

Advertisement

Display and Boiler temperature adjustment
Boiler temperature management is by means of an electronic board in the
machine.
The temperature of the water contained in the boiler can be seen or modified
through the 5 dosing keys.
To see the temperature set, switch on the machine keeping the keys 1+5
pressed.
Keys 1,2 and 3 will start to flash in the following mode (example):
-
key 1 (hundreds) = n° 1 flash
-
key 2 (tens) = n° 2 flashes
-
key 3 (units) = n° 4 flashes
With these flashes, the temperature setpoint is 124 °C.
To modify the temperature setpoint, use keys 4 and 5 as follows:
-
key 4 to decrease
-
key 5 to increase
Switch the machine off, then on again, to save the new temperature setpoint
value.
The settable temperature range is between 120°C and 128°C whereas the
value set in the fqactory is 123°C.
Standby/Economy function
With the Standby/Economy function the machine remains in low consumption
condition by switching off the boiler heating resistors.
The machine can be set in this mode manually with the machine on, by
pressing in sequence keys 5 and 3 or in automatic mode after 20 minutes that
no coffee delivery is requested.
In both cases, when the machine is in Standby/Economy all the keys switch off,
except key 1 that flashes every 2 seconds.
To exit from Standby/Economy, just press one of the 5 dosing keys.
24
Ita
lia
no
D
eu
tsc
h
En
gli
sh
Fr
an
ça
is

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents