General Notes; Tests Before Starting To Operate - Fayat Group BOMAG BW177D-50 Operating Instructions, Maintenance Instructions

Single drum
Table of Contents

Advertisement

General notes

Please read section 3 Indicators and Control Elements
thoroughly before operating the machine if you are
not yet fully familiar with the indicators and control
elements of the machine.
All indicators and control elements are described in
detail in this chapter.
4-2012

Tests before starting to operate

The following tests must be performed before each
work day or before a longer work period.
Danger of accident!
Please observe strictly the safety
regulations in chapter 2 of these
o p e r a t i n g
instructions!
Park the machine on level ground.
Check:
Fuel tank and fuel lines for leaks
Bolted connections for tight fit
Function of the steering
Check the machine for cleanliness and damage
Availability of the appropriate operating and
maintenance instructions,
Check if the machine has been properly serviced.
NOTE: For a description of the following work
refer to the section "maintenance every 10
operating hours"
Engine oil level
NOTE: hydraulic systems, which are filled with
Panolin hLP Synth� 46, the same oil must
be used for filling up� in case of any other
ester based oil consult the lubrication
service department of the respective oil
manufacturer�*
Check the hydraulic oil level, top up if necessary.
Check the coolant level, top up if necessary.
Fire hazard!
Do not refuel in closed rooms
Check the fuel level, top up if necessary.
Check water separator in the fuel system, drain if
necessary.
* Optional equipment