Silent Arm And Disarm; User Selectable Led; Troubleshooting Trigger Zones; Adjusting Shock Sensor - Prestige APS25Z Installation And Reference Manual

Vehicle security / keyless entry system
Hide thumbs Also See for APS25Z:
Table of Contents

Advertisement

Quick Reference: System Programming & Diagnostics

Silent Arm and Disarm

Program the Prestige system to arm and disarm without notification beeps. (The siren will sound if the system is
triggered while armed.)
1. Turn the ignition ON then OFF.
2. Press and release the valet/programming button three (3) times. The system will respond with one (1) beep for ON or
two (2) beeps for OFF.

User Selectable LED

This feature will control whether the LED is ON or OFF when the system is Armed/Locked. This will be selectable in
feature programming OR on-the-fly without entering the programming feature banks.
1. Turn the ignition ON, OFF, ON, OFF.
2. Press and hold valet button for five (5) seconds.
The system will respond with one (1) beep for ON or two (2) beeps for OFF.

Troubleshooting Trigger Zones

Test the doors, hood, trunk, and shock sensor to ensure they trigger the security system. Once triggered, the LED flashes
to indicate the trigger source:
Adjusting the Shock Sensor
1. Arm the system, wait 5-10 seconds, then with an open palm carefully apply impact to areas of the vehicle to test the
shock sensor's sensitivity.
2. To adjust, turn the adjustment knob on the shock sensor counter-clockwise for less sensitivity; clockwise for more
sensitivity.
3. If the proper sensitivity still cannot be achieved, re-locate the shock sensor.