Servicing; Electric Motor Care; Shaft Seal Replacement; Pump Disassembly - STA-RITE SUPERMAX VS Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

Available languages

Available languages

14

SERVICING

Always disconnect power to the SuperMax
before servicing the pump. Failure to do so could result in death or serious injury to service people, users or others due to electric shock.
Read all servicing instructions before working on the pump.
DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in
these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause
serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is
cool to touch, then open with extreme caution.
Be sure not to scratch or mar the polished shaft seal faces; seal will leak if faces are damaged. The polished and lapped faces of the seal
could be damaged if not handled with care.

Electric Motor Care

Protect from heat
1. Shade the motor from the sun.
2. Any enclosure must be well ventilated to prevent
overheating.
3. Provide ample cross ventilation.
Protect against dirt
1. Protect from any foreign matter.
2. Do not store (or spill) chemicals on or near the motor.
3. Avoid sweeping or stirring up dust near the motor
while it is operating.
4. If a motor has been damaged by dirt it may void the
motor warranty.
5. Clean the lid and clamp, O-ring, and sealing surface
of the pump pot.
Protect against moisture
1. Protect from splashing or sprayed water.
2. Protect from extreme weather such as flooding.
3. If motor internals have become wet - let them dry
before operating. Do not allow the pump to operate if it
has been flooded.
4. If a motor has been damaged by water it may void
the motor warranty.

Shaft Seal Replacement

The Shaft Seal consists primarily of two parts, a rotating
member and a ceramic seal.
The pump requires little or no service other than
reasonable care, however, a Shaft Seal may occasionally
become damaged and must be replaced.
Note: The polished and lapped faces of the seal could be
damaged if not handled with care.
SUPERMAX
VS Variable Speed Pump Installation and User' s Guide
®
VS Variable Speed Pump at the circuit breaker and disconnect the communication cable
®

Pump Disassembly

All moving parts are located in the rear sub-assembly of
this pump.
Tools required:
1/4 inch socket or open end wrench.
3/8 inch socket or open end wrench.
9/16 inch open end wrench.
1/4 inch Allen Key
Flat blade screwdriver.
To remove and repair the motor subassembly, follow
the steps below:
1. Press the Start/Stop button to stop the pump and
turn off the pump circuit breaker at the main panel.
2. Drain the pump by removing the drain plugs.
3. Remove the 4 bolts that hold the main pump body
(strainer pot/volute) to the rear sub-assembly.
4. GENTLY pull the two pump halves apart, removing
the rear sub-assembly.
5. Remove the three hex head screws holding the
diffuser in position.
6. Hold the impeller securely in place and remove the
impeller lock screw by using a flat blade screwdriver
or wrench. The screw is a left-handed thread and
loosens in a clockwise direction.
7. To unscrew the impeller from the shaft, insert a 1/4
inch Allen key into the center of the motor fan cover
and twist the impeller counter-clockwise.
8. Remove the four bolts from the seal plate to the
motor using a 9/16 inch wrench.
9. Place the seal plate face down on a flat surface and
tap out the ceramic seal.
10. Clean the seal plate, seal housing, and the motor
shaft.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents