Pressure Drop; Fault Conditions; Details On Energy Consumption - STIEBEL ELTRON PEO 18 Operation And Installation

Electronically controlled instantaneous water heater
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
INSTALLATION
Specification

15.5 Pressure drop

Taps/valves
Tap pressure drop at a flow rate of 10 l/min
Mono lever mixer tap, approx.
Thermostatic valve, approx.
Hand shower, approx.
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1 MPa is recommended.

15.6 Fault conditions

In the event of a fault, loads up to a maximum of 95 °C at a pressure
of 1.2 MPa can occur temporarily in the installation.

15.7 Details on energy consumption

The product data complies with EU regulations relating to the Di-
rective on the ecological design of energy related products (ErP).
Manufacturer
Load profile
Energy efficiency class
Annual power consumption
Energy conversion efficiency
Default temperature setting
Sound power level
Special information on measuring efficiency
16
| PEO 18/21/24 | PEO 27
MPa
0.04 - 0.08
MPa
0.03 - 0.05
MPa
0.03 - 0.15
kWh
%
°C
dB(A)
PEO 18/21/24
233991
STIEBEL ELTRON
S
A
477
39
60
15
Data at Pmax.
www.stiebel-eltron.com
PEO 27
233992
STIEBEL ELTRON
S
A
481
39
60
15
None

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Peo 21Peo 24Peo 27Pey 18Pey 21Pey 24

Table of Contents