Taylor 750 Original Operating Instructions page 31

Soft serve freezers
Hide thumbs Also See for 750:
Table of Contents

Advertisement

Figure 27
Step 4
Place the power switch in the ON position.
Figure 28
Step 5
Press the WASH key. This will cause the sanitizing
solution in the freezing cylinder to agitate. Allow it to
agitate for five minutes.
Figure 29
Models 750, 751, 754, 774, 791, 794
Step 6
Place an empty pail beneath the door spout and raise
the prime plug.
Step 7
When a steady stream of sanitizing solution is flowing
from the prime plug opening in the bottom of the
freezer door, lower the draw handle. Draw off all the
sanitizing solution.
Note: On the Models 754, 774, 791, and 794,
momentarily pull the center draw handle down to
sanitize the center door spout.
Step 8
Once the sanitizer stops flowing from the door spout,
raise the draw handle and press the WASH key,
cancelling the beater motor operation.
Note: You have just sanitized the freezer. Be sure
your hands are sanitized before continuing these
instructions.
27
Figure 30
Figure 31
Operating Procedures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

751754791774794

Table of Contents