Honeywell Accenta Series Engineer's Manual page 39

Table of Contents

Advertisement

Accenta/Optima Engineer's Manual
LCD Keypad:
NOTE:
Pressing the number toggles the zone ON or OFF
While in Engineer program mode, to set up zones as used,
Press [PROG] to give a choice of programs or press
[up arrow] until P>Set Up Programs is displayed then press
[SET].
Select program 1, 2 or 3.
The first screen to appear is Program Edit Used Zones.
Press [1] or [SET]. The first zone can now be set as used or
unused.
To edit the other zones press [Number] or [up arrow] to go to
a particular zone.
Press [RESET] three times to leave menu.
LED Keypad:
NOTE:
Pressing the number toggles the zone ON or OFF
While in Engineer program mode, to set up zones as used,
Press [PROG] to give a choice of programs. LED's 1, 2 and 3 are
flashing.
Select program [1, 2 or 3]. If program 1 is selected, LED 1 is ON.
Press [1] or [SET]. The first zone can now be set as used or
unused. If used, then LED is on
To edit the other zones press [Number] to go to a particular zone.
Default settings are on.
Press [RESET] three times to leave menu.
Programs (cont'd)
P>Select
P>Select
P>Select
P>Select
P>Select
1 2 or 3
1 2 or 3
1 2 or 3
1 2 or 3
1 2 or 3
P>Program Edit
P>Program Edit
P>Program Edit
P>Program Edit
P>Program Edit
1: Descriptor
1: Descriptor
1: Descriptor
1: Descriptor
1: Descriptor
U s e d :
U s e d :
U s e d :
U s e d :
U s e d :
2: Descriptor
2: Descriptor
2: Descriptor
2: Descriptor
2: Descriptor
U s e d :
U s e d :
U s e d :
U s e d :
U s e d :
P>Set Up
P>Set Up
P>Set Up
P>Set Up
P>Set Up
35
[PROG]
Program
Program
Program
Program
Program
[Number]
Used Zones
Used Zones
Used Zones
Used Zones
Used Zones
[1] or [SET]
Y E S
Y E S
Y E S
Y E S
Y E S
[Number] or [up arrow]
N O
N O
N O
N O
N O
[RESET]
Programs
Programs
Programs
Programs
Programs
[PROG]
1
2
3
4
5
6
[1]
1
2
3
4
5
6
[1] or [SET]
1
2
3
4
5
6
[Number]
1
2
3
4
5
6
[RESET]
1
2
3
4
5
6
7
8
7
8
8
7
7
8
7
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optima series

Table of Contents