13. Bobbin winder
42
1
2
Standard:
When the bobbin is full, the winding process should stop automatically.
Setting:
–
Unscrew the cover of the case. As the bobbin winder is connected
to the power supply with cables, lift the cover carefully so that the
cables are not damaged.
–
Loosen screw 1 and turn the block according to the instructions.
–
Tighten screw 1 again.
–
Should the winding process stop too early in spite of optimum
setting, the feeler 2 must be aligned correspondingly.