DURKOPP ADLER 540-100-1 Manual Complete page 161

Table of Contents

Advertisement

Available languages

Available languages

Number
Error position
4304
Memo-Dongle
4307
Memo-Dongle
5101
Contour data-
administration
5104
Contour data-
administration
5301
Contour data-
administration
5303
Contour data-
administration
5305
Contour data-
administration
5306
Contour data-
administration
5315
Contour data-
administration
6151-6952 I²C/ CPU/ Mem-
Manager
7251-7659 ASC/ SSC/
RS485
8151-8351 IDMA/ Xilink/
Test pins
Description
Wrong type
Wrong class
EEPROM not
initialized
Checksum error
Data memory full
Data memory-
overflow
Invalid data storage
attempt
Invalid data request
General error
Cause
Boot-Dongle is inserted Use Memo-Dongle
Dongle of the wrong
class was inserted
- Control
- Control contains no
machine program
- Control
Too many stitches in
contour
Too many stitches in
contour
Too many stitches in
contour
Fault
Fault
Fault
(8151-8159: only an
entry in the event
memory – no further
impairment)
Error elimination
Insert correct Dongle
Format the Dongle
- Check control
- Install machine program
The machine resets itself
automatically.
Inform DA-Service
Reduce number of
stitches
Inform DA-Service
Reduce number of
stitches
Inform DA-Service
Reduce number of
stitches
Inform DA-Service
Carry out buttonhole
contour reset
Inform DA-Service
Carry out buttonhole
contour reset
Inform DA-Service
Switch machine off and
then on again
Inform DA-Service
Switch machine off and
then on again
Inform DA-Service
Switch machine off and
then on again
Inform DA-Service