E. Door Handle Assembly
Installation of Door Handle:
1. Slide door handle shaft through hole on door.
2. Add up to three 3/8 washers on the inside of the door.
NOTE: The quantity of washers added will change how the
door seals. You many need to tear down the handle
assembly a few times to gain the correct seal.
3. Add square key to door handle shaft; may need to use
a rubber mallet to ensure key sits firmly into groove of
door handle shaft.
4. Slide cast iron cam latch over door handle shaft and
locking key.
CAUTION! DO NOT OVER TIGHTEN LOCKING NUT; DOOR
HANDLE NEEDS TO MOVE SMOOTHLY!
Door Cross
Latch Cam
Section
Locknut
3/8 inch
Add up to 3
Spacing
washers on
Washers
this side of
the door
Figure 25.1
F. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for
combustion to take place. Whatever combustion air is
consumed by the fire must be replaced. Air is replaced via
air leakage around windows and under doors. In homes
that have tightly sealed doors and windows, an outside air
source is needed. An optional Outside Air Kit is available.
Optional OAK-ACC includes: Termination cap, (2) wire
ties, flex adapter, and fasteners
Items Needed for Installation (not supplied):
4 inch flex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible,
heat resistant material up to 350
required length for your installation.
Phillips head screw driver
Silicone sealant
Drills and saws necessary for cutting holes through the
wall or flooring in your home.
August 13, 2018
Door Handle Shaft
Square Key
Fiber Handle
o
F. Cut the pipe to the
4300 Wood Appliance Series ACC
Installation Instructions:
1. Remove all materials from packing box.
2. Floor & Rear Installation: Cut a 4 inch (102mm) hole
in outside wall or floor to accommodate outside air
piping. Use 4 inch (102mm) aluminum metal flex or
rigid piping to directly connect outside air to appliance
intake. Use the supplied termination cap with a rodent
screen. Seal between the wall (or floor) and the pipe
with silicone to prevent moisture penetration.
Asphyxiation Risk.
Length of outside air supply duct shall NOT
exceed the length of the vertical height of the
exhaust flue.
Fire will not burn properly
Smoke spillage occurs when door is opened
due to air starvation
For Floor Installa-
tions Remove
Circular "Knock-Out"
in Base of Pedestal.
Flex Line
Figure 25.2
Fire Risk. Asphyxiation Risk.
Do not draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Close proximity to exhaust vents or chimneys
Fumes or odor may result
Asphyxiation Risk.
Outside air inlet must be located to prevent
blockage from:
Leaves
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate
sensitive individuals.
7037-172G
WARNING
Flex Adapter
Wire Tie
Wire Tie
WARNING
WARNING
Snow or ice •
Other debris
Termination
Cap
25