Guzzler Maintenance - Aztec GUZZLER Owner's Manual

High speed solution retriever
Table of Contents

Advertisement

GUZZLER OWNER'S MANUAL PAGE 7

GUZZLER MAINTENANCE

SQUEEGEE ADJUSTMENT
To adjust the squeegee, the three (3) bolts which attach the squeegee will also adjust the squeegee
height. Turn the bolts clockwise (to raise) or counter clockwise (to lower). A 1/2 turn should be enough.
Be sure jam nuts are snug. Check performance and adjust accordingly. See Figure 1 below.
PUMP SERVICE
Cleaning Pump — Remove pump. Wash in warm water. Make sure that all debris is cleared from inlet
and outlet flapper valves. Check for worn parts.
Adjusting Pump Plate — Loosen four nuts holding pump and adjust so black plate is 1/8" from the floor.
Check for wear on foot pedal. See Figure 2 below.
Rebuilding Pump — Remove pump. Replace inlet, outlet and then diaphragm components of the pump.
Only tighten screws until tan hinge gasket starts to squeeze out. Check pump for suction before re-
installing.
REPAIRING LEAKS
Isolate leak:
Fitting Leak — Remove fitting, clean and smooth the surface and/or gasket. Apply silicon and re-install.
Body Leak — Contact Aztec Products, manufacturer.
Figure 1: Correct squeegee profile
Figure 2: Pump plate clearance to floor
12-2018

Advertisement

Table of Contents
loading