Permissible Expansion For Temperature Range 0 To 50 °C - Siemens SIMATIC IPC847E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC847E:
Table of Contents

Advertisement

Expanding and assigning parameters to the device
6.6 Drives
6.6.2.2
Permissible expansion for temperature range 0 to 50 °C
Note
If the device is permanently installed, mounted on telescopic rails or operated as tower, it
can only be subjected to the vibration stresses described below during operation.
The restrictions do not apply to the use of SSD.
The maximum permitted power loss of the expansion cards is 80 W.
You can install the following drives in the Type B drive cage at various mounting locations.
You can find information on the mounting locations under:
● Drive cage type B (Page 18)
Installation options
The following representations give you an overview of the installation options for drives.
If drives are installed in one of the mounting locations, these may be exposed to the
following vibration stresses during operation:
● 10 ... 58 Hz: 0.075 mm
● 58 ... 500 Hz: 5 m/s
116
2
Drive in drive bay for internal
rugged installation
Drive type "SATA" is possible
Operating Instructions, 10/2018, A5E43920357-AA
SIMATIC IPC847E