Siemens SIMATIC IPC847E Operating Instructions Manual page 115

Hide thumbs Also See for SIMATIC IPC847E:
Table of Contents

Advertisement

Vibrations above 500 Hz are not permitted.
If drives are mounted on the side panel, these may be exposed to the following vibration
stresses during operation:
● 10 .... 58 Hz: 0.045 mm
● 58 ... 300 Hz: 3 m/s²
Ambient temperature
Drive configuration
Non-RAID system
RAID1 system
RAID5 system
RAID1 system with hot spare drive
RAID5 system with hot spare drive
Maximum number of drives per drive type
(in drive cage type B or internally on the side panel of the device)
Ambient temperature
Drive type
SATA
SATA Enterprise
* 0 °C minimum permissible temperature for SATA hard disk drive
5°C minimum permissible temperature for SATA Enterprise hard disk drives
SIMATIC IPC847E
Operating Instructions, 10/2018, A5E43920357-AA
Expanding and assigning parameters to the device
6.6 Drives
Additional drive mounted
on the side panel on the
drive bay plate.
Drive type "SATA, SATA
Enterprise" is possible
0 - 40 °C
Mode
X
X
X
X
X
0 * - 40 °C
Front
Side panel
3
2
2
2
115