Midland SP-8 Operation, Parts And Service Manual page 53

Road widener
Table of Contents

Advertisement

NOTICE
Prevent machine damage.
Failure to perform flushing procedure after
a pump, motor or hose failure will result
in a repeat failure and will void machine
warranty.
Either the conveyor loop or traction drive loop can be
flushed, depending on which loop has failed. If there is
a concern that both loops have debris, refer to Flushing
Conveyor And Traction Drive Systems in section 6.4.3.
6.4.1 f
C
lusH
onveyor
Drain and remove hydraulic tank.
1.
Clean or replace both suction strainers and flush
2.
out tank.
Install tank and replacement components.
3.
NOTICE
Prevent machine damage.
Do not pour hydraulic oil directly into
closed loop circuit hoses or a failure will
occur.
In following detail, major steps are mentioned as "Step
#" for dual side machine or as "Step #A" for single
sided machine where applicable. These steps refer to
the schematic description with same headings.
s
1
1A
tep
or
Assemble filter kit using dealer or customer supplied
1.
components as shown below.
www.roadwidener.com
s
ystem
1 - 90° Elbow, 3/4 FNPT x FJIC Swivel
2 - Adapter, 1 MNPT x 3/4 MJIC
3 - Filter Head Donaldson #P166664
4 - Filter, Donaldson #P163555
5 - Adapter, 1 MNPT x 3/4 MNPT
6 - Check Valve, Danfoss #3C14-6-65
7 - Adapter, 3/4 MNPT x 3/4 MNPT
8 - 90° Elbow, 3/4 FNPT x FJIC Swivel
Install filter kit as shown in step 1 or step 1A
2.
in schematics . Connect item #8 directly to pump
fitting. Check valve prevents inadvertent back flow
or back flush into the loop.
If flow and pressure values are required for a new
3.
pump installation, set up flow meter, valve and
gauge in loop prior to flushing. This will insure that
flow meter and gauges do not introduce debris after
flushing.
s
2
2A
tep
or
On operator's console, toggle conveyor direction
1.
switch for right side discharge and turn off flow
control. Right and left side is defined as relative to
operator in seat.
Follow pressure hose back from right side motor
2.
to pump. This should be port "C" on pump. Verify
motor rotation and hoses as follows:
Label and disconnect two hoses at each motor and
3.
connect to each other using a 3/4 MJIC x 3/4 MJIC
adapter. This is shown as step 2 (for dual side) and
2A (for single sided).
Start the engine and slowly increase conveyor flow
4.
until filter's "visual service indicator" is positioned
in center of the window. If pump goes over relief,
the flow is going against check valve. Stop the
flow, then reverse conveyor direction or hoses.
Model SP-8 & 10
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spd-8Sp-10Spd-10