Operation After Gas Or Power Outage; Normal Shutoff - BKI BLG-TC Series Operation Manual

Extra-large gas auto-lift fryer with training central
Table of Contents

Advertisement

Gas Auto-Lift Fryer

Operation after Gas or Power Outage

The fryer may shut off automatically if the gas supply is interrupted or the power goes out. If either of these
conditions occur, you should perform the following procedure:
1. Turn fryer off by touching the Off button for 3 seconds.
2. Wait at least five minutes to allow any gas that may have accumulated in the burner compartment to
escape.
3. Follow normal operating procedures once the power or gas is restored.

Normal Shutoff

1. Turn fryer off by touching the Off button for 3 seconds.
2. Wait at least five minutes to allow any gas that may have accumulated in the burner compartment to
escape.
For your safety, if the gas supply stops, or, if the power goes out, make sure to wait for at
least five minutes before restarting your fryer. This allows time for any unburned gas to
dissipate. (LP gas may take longer than five minutes.) If you smell gas, do not start your
fryer.