Sentera Controls RMFPX-2R Mounting And Operating Instructions

Multifunctional room controller

Advertisement

Quick Links

RMFPX-2R
MULTIFUNCTIONAL
ROOM CONTROLLER
Mounting and operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMFPX-2R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sentera Controls RMFPX-2R

  • Page 1 RMFPX-2R MULTIFUNCTIONAL ROOM CONTROLLER Mounting and operating instructions...
  • Page 2: Table Of Contents

    ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS OPERATING INSTRUCTIONS VERIFICATION OF INSTALLATION INSTRUCTIONS MODBUS REGISTER MAPS TRANSPORT AND STORAGE WARRANTY AND RESTRICTIONS MAINTENANCE MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 2 - 11 www.sentera.eu...
  • Page 3: Safety And Precautions

    In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 3 - 11 www.sentera.eu...
  • Page 4: Product Description

    ► Amendment AC:1993 to EN 60529 - EN 60730-1:2011 Automatic electrical controls for household and similar use - ► Part 1: General requirements MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 4 - 11 www.sentera.eu back to the table of contents...
  • Page 5: Operational Diagrams

    GND terminal should NOT BE CONNECTED to other units on the network or via the CNVT-USB-RS485 converter. This may cause permanent damage to the communication semiconductors and / or the computer! MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 5 - 11 www.sentera.eu...
  • Page 6 MULTIFUNCTIONAL ROOM CONTROLLER MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the RMFPX-2R, read carefully “Safety and Precautions”. Choose a smooth surface for installation (a wall, panel and etc.). Follow these steps: Using a flat screwdriver, remove the front white cover by releasing the snap-fits on its both sides (see Fig.
  • Page 7 Always connect different article types to separate AC transformers or use the same article version. CAUTION Do not expose to direct sunlight! MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 7 - 11 www.sentera.eu back to the table of contents...
  • Page 8: Operating Instructions

    Ambient light sensor The measured light intensity in luxes is available in Input Register 5. Additionally, an active and standby level can be defined in Holding registers 34 and 35. Input MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 8 - 11 www.sentera.eu...
  • Page 9: Verification Of Installation Instructions

    Flag that shows if the communication with the Ambient light sensor fault unsigned int. 0—1 ambient light sensor is lost MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 9 - 11 www.sentera.eu back to the table of contents...
  • Page 10 60—100 60 = 60 % Reserved, returns “0”. If you want to find out more about Modbus over serial line, please visit: http://www.modbus.org/docs/Modbus_over_serial_line_V1_02.pdf MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 10 - 11 www.sentera.eu back to the table of contents...
  • Page 11: Transport And Storage

    In case of heavy pollution, clean with a non-aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW-RMFPX-2R-EN-000 - 23 / 04 / 2018 11 - 11 www.sentera.eu...

Table of Contents