Bailey Approach Autograph Series Owner's Manual page 76

Table of Contents

Advertisement

74
Main Menu
Press MENU button to access the Main Menu
from the Standby Screen or Settings Menu. The
screen will revert to the Standby Screen after
30 secs if untouched.
1. Standby Screen. Press MENU button.
2. Main Menu.
a. What's Activated Menu. (Not displayed
if no activated functions are detected.)
b. Settings Menu
Desired Room Temperature
The desired room temperature can be set from
5 to 30°C, in 0.5 increments.
The World Health Organisation recommends a
room temperature of 18–24°C for healthy living.
NOTE: If Day or Night Mode are
active, the temperature cannot be
adjusted, and the Plus and Minus
buttons will be greyed out.
> The current desired room temperature is
displayed.
> Adjust by pressing either the Plus or Minus
button.
Domestic Hot Water
The Alde boiler stores 8.4 Litres of hot water as
standard. If the hot water cylinder is empty, the
air is heated but no damage will result.
NOTE: If the Day or Night Mode Hot
Water Ignore is active, the hot water
cannot be adjusted. The Plus and
Minus buttons will be greyed out.
> Hot Water Ignore. Volume bar shown empty.
No attempt will be made to heat hot water
specifically. This saves energy when the
fresh water is drained down.
> Hot Water Normal. Volume bar shown half-
full. Hot water is heated to greater than
50 °C. NB: If Circulation Pump is set to
Continuous, this option will not be available.
> Hot Water Boost. Volume bar full. Central
heating circulation is disabled for 30 mins.
Hot water is heated to greater than 65 °C.
After 30 mins the system reverts to Hot
Water Normal.
> Adjust the volume bar by pressing Plus or
Minus button.
Electric Heating
Check that 230V supply is displayed on the
Standby Screen. The Alde boiler is programmed
to use power economically and there are times
when it may use no power at all, even if set to
3 kW.
1. Select 1, 2 or 3 kW electric heating. More
power equals better performance, but may
be restricted by the current (amps) limit on
the electric hook-up.
2. Adjust by pressing Plus or Minus button.
Max current draw from 230V supply is 4.5 Amps
on 1 kW, 9 Amps on 2 kW, 14 Amps on 3 kW. If
the electricity supply has unstable voltage, the
amperage will also fluctuate.