5.5

Installing the unit

When installing the unit, please note the following:
}
For stability reasons, the front panel, console or control cabinet should have a wall
thickness of at least 2.5 mm.
}
To avoid a build-up of heat, a distance of a 10 cm/3.94" should be kept free all round
the system.
}
Ensure the information given for the ambient and operating temperatures in the tech-
nical details is observed.
}
IP65 protection can only be guaranteed when
}
Protect the system against falling down, i.e. ensure that the fixing screws are firmly
tightened.
5.6

PMI 509 Installation

Fig.: PMI 509 Installation
Operating Manual PMI 5
1002241-EN-07
the fixing screws are sufficiently tightened (min. 0.2 Nm).
the gasket is not damaged.
the wall thickness is at least 2.5 mm.
NOTICE
The torque setting for the fixing screws may not exceed 0.3 Nm.
21