3.4 INSTALLATION OF THE CABLE BETWEEN THE DISPLAY UNIT AND THE SCANNER
Cable Wiring
Pin number
1
Blue (thick), gray (thick)
2
Purple (thick), brown (thick)
3
White (thick), orange (thick)
4
Red (thick), green (thick)
5
Black (thick), light blue (thick)
6
Black
Drain line (coaxial)
7
(Drain line: shield, shield meshwork)
8
9
Yellow (thick), pink (thick)
10
Coaxial line core
11
Yellow
12
Green
13
White
Drain line (shield)
14
(Drain line: coaxial, shield meshwork)
15
Shield line core
16
Orange (medium)
Shield meshwork
Cover
(Drain line, coaxial, drain line shield)
* Outer diameter of the cable: 14 mm +/-0.5 mm
Reference:
Although a cable is not connected to PIN No.8, +12 V voltage is outputted to the display
unit side. Power for the external simulator is supplied by this +12 V power supply outlet. So,
avoid using this connection for other purposes to prevent short-circuits.